Skip to main content
Schneider Electric ATV6000D750A4242ND

Schneider ATV6000D750A4242ND Altivar Process drive, 750 kVA

MPN ATV6000D750A4242ND
Active

Schneider Electric Altivar Process ATV6000, model ATV6000D750A4242ND, 750 kVA apparent power, 3-phase input, 24-pulse diode rectifier, 600 kW normal duty / 480 kW heavy duty, floor-standing enclosure.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV6000D750A4242ND specifications
ParameterValue
Input type24 pulse diode rectifier bridge
Display type10 inch LCD touch screen multi-language
Connector type2 RJ45 on the control block)Ethernet IP/Modbus TCP 1 RJ45 on the control block)Modbus serial
Current83 A heavy duty 104 A normal duty
Frequency50 Hz +/- 5 %
Phases3-phase
IP ratingIP31
Temp storage max50 °C
Temp storage min0 °C
Temp operating max60 °C
Temp operating min1.2 °C
Storage temperature32...122 °F (0...50 °C)
Pollution degreePollution degree 2
Depth55.1 in (1400.0 mm)
Width104.7 in (2660.0 mm)
Height99.9 in (2537.0 mm)
Operating temperature32...104 °F (0...40 °C) 104...122 °F (40...50 °C) with derating factor -13...158 °F (-25...70 °C) during transport

Product details

The Schneider Electric ATV6000D750A4242ND is a current-production Altivar Process ATV6000 medium-voltage drive, delivering 750 kVA apparent power with a 24-pulse diode rectifier input that keeps line THDI below 3% per IEEE 519-1992 — no external filter needed for that spec. It's rated 600 kW normal duty, 480 kW heavy duty, with a 96% power factor and an integrated EMC filter (C3 control side, C4 power). The enclosure sits at 104.7 x 99.9 x 55.1 inches and includes the phase-shifting transformer, power cells, cooling fans, HMI, and cabinet cooling.

The 600 kW normal duty / 480 kW heavy duty rating sets the continuous and overload capability — heavy duty for constant-torque loads (conveyors, extruders) and normal duty for variable-torque (pumps, fans). The 24-pulse input, combined with the phase-shifting transformer, suppresses the 5th and 7th harmonics to meet IEEE 519 without an active front end. Protection covers line over/undervoltage, phase loss, DC bus overvoltage, thermal overload on the transformer, cabinet overtemperature, output overcurrent/short-circuit, IGBT faults, motor phase/earth faults, and fan monitoring. The 10-inch LCD touchscreen provides multi-language access to diagnostics and commissioning.

Marked CULus, CE, UKCA — suitable for North American and European installations. Standards include IEC 61800-3 (EMC), IEC 61800-5-1 (safety), IEEE 519, and UL 347A. The isolation between power and control is electrical. Pollution degree 2 per IEC 61800-5-1.

MPN
ATV6000D750A4242ND