Skip to main content
Schneider Electric ATV6A0C20Q6

Schneider ATV6A0C20Q6 Altivar Process Drive, 200 kW

MPN ATV6A0C20Q6
Active

Schneider Electric Altivar Process ATV6A0C20Q6, modular 200 kW VFD, 690 V, integrated C3 EMC filter, STO SIL 3.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV6A0C20Q6 specifications
ParameterValue
Main product or component typeVariable speed drive
Current200.0 A 690 V normal duty) 163.0 A 690 V heavy duty)
Frequency50...60 Hz - 5...5 %
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min1.1 °C
Storage temperature-40...158 °F (-40...70 °C)
Pollution degreePollution degree 2
Data format8 bits, configurable odd, even or no parity Modbus serial
Operating temperature14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor

Product details

What this ATV6A0C20Q6 covers

The ATV6A0C20Q6 is a Schneider Electric Altivar Process ATV600 drive rated for 200 kW at 690 V in normal duty, 160 kW in heavy duty. It handles asynchronous and synchronous motors, with line current at 200 A (normal) or 163 A (heavy). This is the modular version — separate power module and control unit shipped together with mechanical mounting kits and fuses. It means you can swap the control section without pulling the whole frame if a fieldbus card fails.

Ratings that matter on the floor

Integrated EMC filter to IEC 61800-3 category C3 saves a line reactor or external filter for most industrial environments. The drive's THDI stays under 48% at full load per IEC 61000-3-12, so it won't trash your panel distribution. Pair it with a suitable safety relay or controller. Switching frequency runs 2 to 4.9 kHz adjustable, with derating above 4 kHz. For 200 kW motor cables, keep it at 2–3 kHz unless you want to derate output current.

Mounting and wiring quick notes

Cabinet mount only — UL Type 1 or Type 12 when integrated into an enclosure. Forced convection cooling keeps the heat moving; make sure your cabinet ventilation handles the dissipation. Line and motor connections use M10 screw bars on the power module. The control section has slot A for fieldbus options (Profibus, PROFINET, DeviceNet, CANopen, Modbus TCP) and slot A/B for digital/analog I/O or relay extension. Modbus serial is on RS-485 2-wire, RTU format, 1 to 247 addresses at 4.8-38.4 kbps. Ethernet/Modbus TCP at 10/100 Mbps with half/full duplex and auto-neg. No MODBUS bridge built-in; the serial and Ethernet ports are independent.

MPN
ATV6A0C20Q6