Skip to main content
Schneider Electric ATV6A0C35R4

Schneider Electric ATV6A0C35R4 Altivar Process 600, 355 kW

MPN ATV6A0C35R4
Active

Schneider Electric Altivar Process ATV600, modular drive, 355 kW at 440 V normal duty / 280 kW heavy duty, 559 A line current, integrated EMC filter C3 to 300 m, STO SIL3, CE marked.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV6A0C35R4 specifications
ParameterValue
Main product or component typeVariable speed drive
Current559.0 A at 440 V (normal duty) 450.0 A at 440 V (heavy duty)
Frequency50...60 Hz - 5...5 %
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min1.1 °C
Storage temperature-40...70 °C
Pollution degree2 conforming to IEC 61800-5-1

Product details

The ATV6A0C35R4 is a modular Altivar Process ATV600 drive rated for 355 kW at 440 V in normal duty and 280 kW in heavy duty, with a corresponding line current of 559 A at 440 V (normal) or 450 A (heavy). That makes it the right fit for a 355 kW motor on a process pump or fan, and the heavy-duty rating handles the higher current demand of a constant-torque load like a conveyor without oversizing the drive. It ships as a kit: one control unit, three 160 kW power modules, front covers, mounting hardware, and power connections. That modular build means if a power module takes a hit, you swap just that section — not the whole drive. No shop, no crane, fix it where it sits. On the safety front it carries STO (Safe Torque Off) rated SIL 3, plus thermal, overcurrent, short-circuit, and ground-fault protections on both motor and drive sides. Any safety-instrumented system specifying SIL 3 can land here without an external safety relay for the torque-off function.

Power supplies and control wiring

Digital inputs need an external 24 V DC supply (19…30 V). The drive also provides an internal 24 V DC supply for digital inputs and STO (21…27 V, <200 mA) with overload and short-circuit protection — so if your control voltage is stable, you can power the inputs from the drive itself and save an external PSU. There's a separate 10.5 V DC reference supply for the potentiometer (1 to 10 kOhm). Analog inputs: software-configurable 0…10 V DC or 0/4…20 mA, 12-bit resolution. Sampling time 5 ms ±0.1 ms per input. Cabinet mount only, forced-convection cooling. Pollution degree 2 per IEC 61800-5-1 means it expects a clean indoor environment — no conductive dust or condensation.

The kit composition includes three 160 kW power modules — so if one fails, you can replace it individually rather than the whole drive. Keep a spare power module on the van for quick field swaps; the control unit and front covers are separate line items if needed.

MPN
ATV6A0C35R4