Skip to main content
Schneider Electric ATV6B0C11Q4

ATV6B0C11Q4 Altivar Process 110 kW, 175 A

MPN ATV6B0C11Q4
Active

Schneider Altivar Process ATV600 series, ATV6B0C11Q4 modular drive, 110 kW normal duty / 90 kW heavy duty at 400 V, 175 A line current, integrated EMC filter Category C3, STO SIL3 safety.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV6B0C11Q4 specifications
ParameterValue
Main product or component typeVariable speed drive
Current175.0 A at 400 V (normal duty) 144.0 A at 400 V (heavy duty)
Frequency50...60 Hz - 5...5 %
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min1.1 °C
Storage temperature-40...70 °C
Pollution degree2 conforming to IEC 61800-5-1

Product details

What this drive delivers for your project schedule

The ATV6B0C11Q4 is the 110 kW modular drive from the Altivar Process ATV600 family, designed to hit the motor control milestone for pumps, fans, and conveyors in your project. It's the version with the integrated EMC filter (C3) up to 300 m cable, so you can skip an external filter in many installations—saving panel space and wiring time. Rated for 175 A normal duty at 400 V, it delivers 110 kW for typical centrifugal loads; heavy duty rating is 90 kW for constant torque applications.

Cabinet mounting and cooling

Cabinet mount with forced convection cooling. At 2.5 kHz switching frequency, normal duty dissipation is 4180 W; factor that into your cabinet cooling budget. The drive accepts a communication module in Slot A—choose Profibus DP, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, or CANopen to match your automation backbone. Slot A and Slot B also accept digital/analog I/O extension or output relay modules. Line-side connection is via screw terminals; motor connection uses M10 bars. Control wiring uses removable screw terminals accepting 0.5–1.5 mm² / AWG 20–16. Keep the switching frequency adjustable between 2 and 8 kHz with derating factor. STO SIL 3 safety function is built in, so you can wire the safety relay directly without an external safety module. It also includes thermal protection for motor and drive, overcurrent, overvoltage, undervoltage, phase loss, and overspeed protection.

Standards compliance and spares planning

For project procurement, this drive is available now against an RFQ. Plan a spare control module for startup—same communication card slot keeps commissioning spare ready. The integrated EMC filter (C3) with 300 m cable capability reduces external filter count and panel complexity.

MPN
ATV6B0C11Q4