Skip to main content
Schneider Electric ATV6B0C35T4

Schneider ATV6B0C35T4 AC Drive 480V, 550 HP ND, 450 HP HD

MPN ATV6B0C35T4
Active

Schneider Electric Altivar Process ATV600 series, ATV6B0C35T4 modular AC drive, 480 V, 550 HP normal duty / 450 HP heavy duty, 443 kVA, cabinet mount, integrated EMC filter C3, STO SIL 3.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV6B0C35T4 specifications
ParameterValue
Main product or component typeVariable speed drive
Current533.0 A 480 V normal duty) 436.0 A 480 V heavy duty)
Horsepower550.0 hp at 480 V normal duty 450.0 hp at 480 V heavy duty
Frequency50...60 Hz - 5...5 %
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min1.1 °C
Storage temperature-40...158 °F (-40...70 °C)
Pollution degreePollution degree 2

Product details

Motor sizing: the ND vs HD split decides your real load

The ATV6B0C35T4 carries two distinct ratings: 550 HP at 480 V in normal duty and 450 HP at 480 V in heavy duty, with corresponding apparent power of 443 kVA ND and 362 kVA HD. Heavy duty typically applies to constant-torque loads like conveyors or extruders; normal duty suits variable-torque fans and pumps where the headroom isn't needed. Line current at 480 V is 533 A for normal duty and 436 A for heavy duty. The switching frequency is adjustable from 2 to 8 kHz, but above 2.5 kHz a derating factor applies — if you need quieter motor operation at higher carrier frequencies, the output current ceiling drops proportionally. Prospective line short-circuit current (SCCR) is 50 kA. That is high enough for most industrial mains, but the upstream breaker must be coordinated to keep the drive protected — check the selective coordination tables in the installation manual.

Fieldbus and control: what ships on the base unit

The drive includes a Modbus serial port (2-wire RS-485, RTU frame, 1-247 addresses) and a Modbus TCP/Ethernet port (10/100 Mbit/s, half/full duplex, auto-negotiation). Slot A accepts optional communication modules for Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, or CANopen (daisy chain RJ45, SUB-D 9, or screw terminals). The data format on Modbus serial is 8 bits with configurable odd, even, or no parity. For Ethernet/IP, the transmission rate is 10/100 Mbit/s — no speed negotiation issues with modern switches.

Safety and protection: STO SIL 3 and the protection map

That means the drive can be used in safety circuits up to SIL 3 without external contactors for the torque removal function — the drive's own power stage is the isolating element. The protection suite covers both motor and drive sides: thermal protection, motor phase break, overcurrent between output phases and earth, short-circuit protection, overvoltage on the DC bus, line supply over/undervoltage, line phase loss, and overspeed. For the motor, it also includes thermal protection and phase break detection.

Environmental limits and installation constraints

Operating altitude is 1000 to 4800 m with current derating above 1000 m — at 2000 m expect roughly a 10% output current reduction. The drive is cabinet mount only (UL Type 1 or Type 12 per UL 61800-5-1 when integrated into an enclosure). Vibration resistance is 1.5 mm peak-to-peak from 2 to 13 Hz and 0.5 gn from 13 to 200 Hz per IEC 60068-2-6. Shock resistance is 4 gn for 11 ms per IEC 60068-2-27. Relative humidity range is 5 to 95% without condensation per IEC 60068-2-3. The integrated EMC filter covers 300 m of motor cable per IEC 61800-3 category C3 — that is the second environment (industrial mains). For first-environment (residential) installations, an external filter may be needed.

Lifecycle and sourcing: active, modular, quoted to order

The kit composition includes: 1 control unit, mechanical mounting kits, power connection set, set of fuses, 1 power module (160 kW), and 1 front cover. Marking is CE, confirming conformity with EU directives. Standards compliance includes IEC 61800-3 (EMC), IEC 61800-5-1 (safety), IEC 61000-3-12 (harmonic limits), IEC 60721-3 (environmental conditions), IEC 61508 and IEC 13849-1 (functional safety).

MPN
ATV6B0C35T4