Skip to main content
Schneider Electric ATV930D37N4Z

Schneider ATV930D37N4Z Altivar Process 930, 37 kW Normal Dut

MPN ATV930D37N4Z
Active

Schneider Altivar Process ATV900, ATV930D37N4Z variable speed drive, 37 kW normal duty / 30 kW heavy duty, 74.5 A continuous, IP21, 380-480 V three-phase, with braking chopper and integrated EMC filter.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV930D37N4Z specifications
ParameterValue
Main product or component typeVariable speed drive
Phases3-phase
IP ratingIP21
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-40 °C
Storage temperature-40...158 °F (-40...70 °C)
Pollution degree2
ApplicationIndustrial Application
Operating positionVertical +/- 10 degree

Product details

Drive specs and signal reality

The ATV930D37N4Z is a 37 kW normal-duty / 30 kW heavy-duty variable speed drive from the Altivar Process ATV900 family, built for 380-480 V three-phase supplies. Its 74.5 A continuous output at 4 kHz switching (normal duty) and 61.5 A heavy duty give you clean headroom for standard 37 kW induction or synchronous motors, as long as the mounting position stays within ±10° of vertical and the ambient stays below the listed derating curve. The integrated EMC filter keeps conducted emissions within IEC 61800-3 without an external plate, and the THDI stays under 48% from 80-100% load per IEC 61000-3-12 – meaning less harmonic noise on the line than many drives in this class. Noise from the fan runs 71.5 dB; if that matters for a quiet corner of a plant, factor in enclosure or remote mounting.

Certifications on file include UL 508C, IEC 61800-3 (EMC), IEC 61800-5-1 (safety), IEC 61508 and IEC 13849-1 for functional safety, plus pollution degree 2 and overvoltage category III. The documentation package covers the compliance paperwork most plants require.

Mounting and environment check

Cabinet mount, IP21 – so it's for indoor, clean-ish panels. The heat sink dissipates 240 m³/h cooling airflow. Keep the altitude under 1000 m for full rating; above that, derate by 1% per 100 m up to 4800 m. Vibration at 1 gn from 13-200 Hz and shock at 15 gn for 11 ms are solid for most industrial floors, but if you're mounting it on a shaker, bolt through the mounting feet properly. Network options: Modbus TCP, Modbus serial, and EtherNet/IP are on the base board. Slot A accepts Profibus DP V1, PROFINET, DeviceNet, EtherCAT, or CANopen modules – pick the option module that matches your control bus. Wires for the control screw terminals accept 0.5-1.5 mm², which covers most signal and digital input runs. The digital inputs need an external 24 V DC supply (19-30 V). Internal 10.5 V DC drives the reference potentiometer, and a separate internal 24 V DC (21-27 V) feeds the digital inputs and STO safety function. Separate the supply rails – noisy shared supplies are the first thing I'd check if the drive throws a fault on power-up.

MPN
ATV930D37N4Z