Skip to main content
Schneider Electric ATV9A0C50T6

Schneider ATV9A0C50T6 ATV900 Drive, 550 hp, 600 V

MPN ATV9A0C50T6
Active

Schneider Electric Altivar Process ATV900, Modular version, 550 hp at 600 V normal duty, integrated EMC filter category C3, Safe Torque Off SIL 3, dual protocol Ethernet and serial Modbus.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV9A0C50T6 specifications
ParameterValue
Main product or component typeVariable speed drive
Current464.0 A 600 V normal duty) 383.0 A 600 V heavy duty)
Horsepower550.0 hp at 600 V normal duty 450.0 hp at 600 V heavy duty
Frequency50...60 Hz +/- 5 %
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min1.2 °C
Storage temperature-40...158 °F (-40...70 °C)
Pollution degreePollution degree 2

Product details

The ATV9A0C50T6: Cabinet-mount Altivar Process ATV900 rated 550 hp at 600 V normal duty (464 A line current) and 450 hp heavy duty (383 A). Switching frequency adjustable 2–4.9 kHz with derating; suits standard induction and synchronous motors. Integrated EMC filter rated for 984.3 ft (300 m) cable at IEC 61800-3 category C3 level – no external filter needed for most industrial environments. Safe Torque Off SIL 3 included on the control board; break on the control circuit drive protection covers the loop.

Current production – no end-of-life notice. Standard lead times apply; RFQ for firm pricing and availability. CE marked, complies with IEC 61800-5-1, UL 61800-5-1, IEC 61508, and IEC 13849-1 for functional safety. Pollution degree 2 per IEC 61800-5-1. Documentation pack includes declaration of conformity for CE/UKCA; RoHS/REACH declarations available on request.

Control and supply wiring

Digital inputs powered from an external 24 V DC supply (19–30 V); a separate 24 V feed (21–27 V) runs the STO logic. Internal 10.5 V DC ±5% reference for a 1–10 kΩ potentiometer. Control terminals are removable screw, 0.5–1.5 mm² (AWG 20–16). Motor connection via M10 bars. Forced convection cooling; cabinet must provide IP21 or IP54 via the enclosure. UL type 1/12 when integrated.

Fieldbus and options

Comes standard with dual Ethernet (Modbus TCP / EtherNet/IP) at 10/100 Mbit/s and a two-wire RS-485 Modbus serial link (RTU frame, 1–247 addresses). Slot A accepts Profibus DP V1, PROFINET, DeviceNet, EtherCAT, or CANopen (RJ45, SUB-D 9, or screw terminals). Slots B and C accept I/O or relay extensions. Line current at 600 V: 464 A normal duty, 383 A heavy duty. Prospective short-circuit current 50 kA.

MPN
ATV9A0C50T6