Skip to main content
Schneider Electric ATV9A0M10T4

Schneider ATV9A0M10T4 ATV900 Drive, 1000 hp Normal Duty

MPN ATV9A0M10T4
Active

Schneider Altivar Process ATV900 modular drive, ATV9A0M10T4, 1000 hp normal duty at 480 V, 800 hp heavy duty, STO SIL 3, integrated EMC filter category C3.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV9A0M10T4 specifications
ParameterValue
Main product or component typeVariable speed drive
Current1472.0 A 480 V normal duty) 1268.0 A 480 V heavy duty)
Horsepower1000.0 hp at 480 V normal duty 800.0 hp at 480 V heavy duty
Frequency50...60 Hz +/- 5 %
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min1.2 °C
Storage temperature-40...158 °F (-40...70 °C)
Pollution degreePollution degree 2
Data format8 bits, configurable odd, even or no parity Modbus serial
Operating temperature23...104 °F (-5...40 °C) without derating 104...122 °F (40...50 °C) with derating factor

Product details

Switching frequency and derating

The ATV9A0M10T4: The switching frequency is adjustable from 2.5 kHz to 8 kHz in 2 kHz steps, with a derating factor applied above the factory default. At 8 kHz the drive’s rated output current is reduced per the datasheet thermal curve. For installations that require quiet motor operation (e.g., HVAC) the upper range is usable with appropriate headroom.

Safety function and compliance

The drive meets IEC 61800-5-1 and UL 61800-5-1 for electrical safety. Integrated EMC filter complies with IEC 61800-3 category C3, allowing up to 300 m of shielded motor cable per the datasheet. Pollution degree 2 per IEC 61800-5-1.

Communication and control power

Built-in Modbus serial RTU (2-wire RS-485, 4.8–38.4 kbps) and Ethernet Modbus TCP/IP (10/100 Mbit/s). Three option slots (A, B, C) accept fieldbus modules for Profibus DP, PROFINET, DeviceNet, EtherCAT, CANopen, as well as digital/analog I/O, relay, and encoder interfaces. The control supply requires 24 V DC (19–30 V) for digital inputs; an internal supply provides 10.5 V DC ±5 % for a reference potentiometer (1–10 kΩ) and a separate 24 V DC (21–27 V) rail for STO and input power.

MPN
ATV9A0M10T4