Skip to main content
Schneider Electric ATV9B0C56R4

Schneider Electric ATV9B0C56R4 Altivar Process ATV900, 560 k

MPN ATV9B0C56R4
Active

Schneider Electric Altivar Process ATV900, modular drive, ATV9B0C56R4, 560 kW at 440 V normal duty, 450 kW heavy duty, STO SIL 3, integrated EMC filter C3.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV9B0C56R4 specifications
ParameterValue
Connector type2 RJ45 for Ethernet IP/Modbus TCP on terminal 1 RJ45 for Modbus serial on terminal
Main product or component typeVariable speed drive
Current789.0 A at 440 V (normal duty) 634.0 A at 440 V (heavy duty) 684.6 A at 440 V regenerative mode (normal duty) 550.1 A at 440 V regenerative mode (heavy duty)
Frequency50...60 Hz +/- 5 %
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min1.2 °C
Storage temperature-40...70 °C
Pollution degree2 conforming to IEC 61800-5-1
Data format8 bits, configurable odd, even or no parity for Modbus serial

Product details

The ATV9B0C56R4: The 560 kW normal duty figure is the headline — that is the motor power you can drive continuously on a standard pump or fan load. The 450 kW heavy duty rating covers constant-torque applications like conveyors or extruders where the drive must hold torque at low speed. Both are at 440 V three-phase; if your line voltage differs, the apparent power figures (601 kVA normal, 483 kVA heavy) give you the scaling factor. Switching frequency is adjustable from 2.5 to 8 kHz, with derating above the default. For a motor cable run under 300 m, the integrated EMC filter meets IEC 61800-3 category C3 — that covers most industrial environments without an external filter.

Fieldbus and I/O options

The drive ships with two RJ45 ports for Ethernet IP/Modbus TCP and one RJ45 for Modbus serial (RS-485, 2-wire, RTU frame). Slot A accepts Profibus DP V1, PROFINET, DeviceNet, CANopen, or EtherCAT communication modules. Slots B and C handle digital/analog I/O expansion, relay outputs, and encoder interfaces (digital 5/12 V, analog, resolver). That means you can match the fieldbus to your existing control architecture without a protocol gateway.

MPN
ATV9B0C56R4