Schneider Electric ATV9B0C56R4 — AC Drive (VFD) 480V

Schneider Electric ATV9B0C56R4 Altivar Process ATV900, 560 k

MPNATV9B0C56R4
Active

Schneider Electric Altivar Process ATV900, modular drive, ATV9B0C56R4, 560 kW at 440 V normal duty, 450 kW heavy duty, STO SIL 3, integrated EMC filter C3.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV9B0C56R4 — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV9B0
Product range / familyAltivar Process ATV900

Power & Output

ATV9B0C56R4 — Power & Output
ParameterValue
Motor power (kW)560.0 kW at 440 V normal duty 450.0 kW at 440 V heavy duty 560.0 kW at 440 V normal duty regenerative mode 450.0 kW at 440 V heavy duty regenerative mode
Continuous output current1020.0 A at 2.5 kHz normal duty 830.0 A at 2.5 kHz heavy duty 1020.0 A at 2.5 kHz normal duty regenerative mode 830.0 A at 2.5 kHz heavy duty regenerative mode
Max. transient current1224.0 A during 60 s (normal duty) 1245.0 A during 60 s (heavy duty) 1224.0 A during 60 s regenerative mode (normal duty) 1245.0 A during 60 s regenerative mode (heavy duty)
Apparent power601.0 kVA at 440 V normal duty 483.0 kVA at 440 V heavy duty 521.7 kVA at 440 V normal duty regenerative mode 419.2 kVA at 440 V heavy duty regenerative mode

Input / Supply

ATV9B0C56R4 — Input / Supply
ParameterValue
Rated supply voltage range440 V - 15...10 %
Input line current789.0 A at 440 V (normal duty) 634.0 A at 440 V (heavy duty) 684.6 A at 440 V regenerative mode (normal duty) 550.1 A at 440 V regenerative mode (heavy duty)
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for digital inputs: 24 V DC (19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO: 24 V DC (21...27 V), 1 MOhm at 500 V DC, 1 min, earth

Control & Performance

ATV9B0C56R4 — Control & Performance
ParameterValue
Output frequency range0.1...599 Hz
Asynchronous motor control modesOptimized torque mode Variable torque standard Constant torque standard
Synchronous motor control modesPermanent magnet motor Synchronous reluctance motor

Protection & EMC

ATV9B0C56R4 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated with 300 m conforming to IEC 61800-3 category C3
Protection functionsThermal protection: motor Safe torque off: motor Motor phase break: motor Thermal protection: drive Safe torque off: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6

Mechanical & Cooling

ATV9B0C56R4 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP00 (for IP21 or IP54 cabinet integration) conforming to IEC 61800-5-1 IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 60529
Acoustic noise level77 dB conforming to 86/188/EEC
Cooling methodForced convection

Environmental

ATV9B0C56R4 — Environmental
ParameterValue
Operating ambient temperature-5...40 °C without derating 40...50 °C with derating factor
Operating altitude0...4800 m with current derating above 1000m
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3
Storage / transport temperature-40...70 °C
Pollution degree2 conforming to IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6

Approvals

ATV9B0C56R4 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1

Communication

ATV9B0C56R4 — Communication
ParameterValue
Communication protocolsEtherNet/IP Modbus serial Modbus TCP

Product details

The ATV9B0C56R4: The 560 kW normal duty figure is the headline — that is the motor power you can drive continuously on a standard pump or fan load. The 450 kW heavy duty rating covers constant-torque applications like conveyors or extruders where the drive must hold torque at low speed. Both are at 440 V three-phase; if your line voltage differs, the apparent power figures (601 kVA normal, 483 kVA heavy) give you the scaling factor. Switching frequency is adjustable from 2.5 to 8 kHz, with derating above the default. For a motor cable run under 300 m, the integrated EMC filter meets IEC 61800-3 category C3 — that covers most industrial environments without an external filter.

Fieldbus and I/O options

The drive ships with two RJ45 ports for Ethernet IP/Modbus TCP and one RJ45 for Modbus serial (RS-485, 2-wire, RTU frame). Slot A accepts Profibus DP V1, PROFINET, DeviceNet, CANopen, or EtherCAT communication modules. Slots B and C handle digital/analog I/O expansion, relay outputs, and encoder interfaces (digital 5/12 V, analog, resolver). That means you can match the fieldbus to your existing control architecture without a protocol gateway.

Frequently asked questions

What are the key power ratings for this drive?

Motor power is 560 kW at 440 V normal duty and 450 kW at 440 V heavy duty. Line current is 789 A normal duty, 634 A heavy duty.

What safety functions does it support?

Safe torque off (STO) rated SIL 3 per IEC 61508 and IEC 13849-1.

What fieldbus options are available?

Integrated Ethernet IP/Modbus TCP and Modbus serial RS-485. Slot A accepts Profibus DP V1, PROFINET, DeviceNet, CANopen, or EtherCAT modules.

What compliance standards does it meet?

It complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. Marked CE.

MPN
ATV9B0C56R4