Skip to main content
Schneider Electric ATV9B0C71Q4

Schneider ATV9B0C71Q4 Altivar Process ATV900, 710 kW, 1094 A

MPN ATV9B0C71Q4
Active

Schneider Electric Altivar Process ATV900, modular drive, 710 kW at 400 V normal duty, 1094 A line current, STO SIL 3, integrated EMC filter C3.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV9B0C71Q4 specifications
ParameterValue
Connector type2 RJ45 for Ethernet IP/Modbus TCP on terminal 1 RJ45 for Modbus serial on terminal
Main product or component typeVariable speed drive
Current1094.0 A at 400 V (normal duty) 868.0 A at 400 V (heavy duty) 959.7 A at 400 V regenerative mode (normal duty) 753.0 A at 400 V regenerative mode (heavy duty)
Frequency50...60 Hz +/- 5 %
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min1.2 °C
Storage temperature-40...70 °C
Pollution degree2 conforming to IEC 61800-5-1
Data format8 bits, configurable odd, even or no parity for Modbus serial

Product details

The Schneider ATV9B0C71Q4 is an Altivar Process ATV900 modular drive sized for a 710 kW asynchronous or synchronous motor at 400 V normal duty, pulling 1094 A line current. Heavy-duty rating drops to 560 kW / 868 A. Regenerative-mode figures sit at 710 kW / 959.7 A normal duty and 560 kW / 753 A heavy duty — useful if you're feeding energy back into the DC bus on a decelerating load. Control power comes from three separate 24 V DC rails: one for digital inputs (19...30 V), one for STO (21...27 V), and a 10.5 V DC ±5 % reference supply for a 1 to 10 kΩ potentiometer. Keep the STO supply clean — it's the safety path. Switching frequency is adjustable from 2 to 8 kHz, with a derating factor applied above 2.5 kHz. The integrated EMC filter meets IEC 61800-3 category C3 for 300 m of motor cable — enough for most installations without an external filter.

Fieldbus and I/O slots

Three option-card slots (A, B, C) accept communication modules for Profibus DP V1, PROFINET, DeviceNet, CANopen, EtherCAT, or Ethernet IP/Modbus TCP via the two RJ45 ports on the terminal. Slot A also takes digital/analog I/O extension or output relay modules; slots B and C handle encoder interface modules (digital 5/12 V, analog, or resolver). The Modbus serial port runs at 4.8 to 38.4 kbit/s on a 2-wire RS-485 bus, RTU frame, up to 247 addresses.

MPN
ATV9B0C71Q4