Schneider Electric C063N360FM

Schneider Electric C063N360FM ComPacT NS Circuit Breaker, 63

MPN C063N360FM
Active

Schneider Electric ComPacT NS new generation, C063N360FM, 3P fixed circuit breaker, 630 A, MicroLogic 6.0 electronic trip unit, 50 kA Icu at 415 V AC, manually operated.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C063N360FM key specifications
ParameterValue
Control typeManually operated
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Utilization categoryCategory B
IP ratingIP40
Terminal pitch70 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C

All specifications

C063N360FM additional specifications
ParameterValue
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degree3 conforming to IEC 60947
Depth147 mm
Width210 mm
Height327 mm
Electrical life cycles2000 cycles at 690 V In 4000 cycles at 690 V In/2 5000 cycles at 440 V In 6000 cycles at 440 V In/2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric C063N360FM is a ComPacT NS new generation fixed-mount circuit breaker, rated 630 A at 50 °C with a MicroLogic 6.0 electronic trip unit. It's a three-pole unit (3P) built to EN/IEC 60947-2, giving you LSI protection — overload (long time), short-time short-circuit, and instantaneous short-circuit — plus ground-fault (G) on the same trip unit. Breaking capacity lands at 85 kA Icu at 240 V AC and holds at 50 kA Icu at 415 V AC — that's the N breaking capacity code, meaning it's sized for most distribution panels where the fault current doesn't exceed 50 kA at 415 V.

Ratings that matter for the install

The 630 A frame is the same physical size as the rest of the ComPacT NS630b...1600 range — 210 mm wide, 327 mm tall, 147 mm deep — so if you're swapping out an older NS630b, the footprint and backplate mounting holes line up. The fixed-mount version bolts directly to a backplate; no DIN rail here, so plan for a drilled panel. Power losses are 10 W steady-state, which is low enough that you don't need forced ventilation in a standard IP40 enclosure. Thermal memory is 20 minutes — after a trip, the MicroLogic 6.0 remembers the thermal history for that window, so a hot restart won't nuisance-trip on a second start.

Mounts on a backplate with a 70 mm connection pitch. Front connections both top and bottom — upside and downside — so straight-through busbar layouts work without flipping the breaker. IK07 impact rating means it survives a tool drop during commissioning. Four red LEDs for fault indication, one yellow for overload — you can read the trip cause at a glance without pulling the cover. Manually operated, no motor operator fitted as standard, but the range supports add-on rotary handles and shunt trips if you need remote trip.