C080H360FM key specifications
ParameterValue
Control typeManually operated
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Utilization categoryCategory B
IP ratingIP40
Terminal pitch70 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C

All specifications

C080H360FM additional specifications
ParameterValue
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degree3 conforming to IEC 60947
Depth147 mm
Width210 mm
Height327 mm
Electrical life cycles2000 cycles at 690 V In 4000 cycles at 690 V In/2 5000 cycles at 440 V In 6000 cycles at 440 V In/2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

What this 800 A breaker brings to a distribution panel

The Schneider C080H360FM is a ComPacT NS new generation 3-pole circuit breaker rated 800 A at 50 °C, carrying a MicroLogic 6.0 electronic trip unit. The H breaking capacity code means 85 kA Icu at 220/240 V AC and 70 kA at 380/415 V AC — enough to handle high-fault utility feeds without cascading upstream. The trip unit covers L (long-time overload), S (short-time short-circuit), I (instantaneous), and G (ground fault) protection, all configurable via the front interface. It is manually operated, fixed-mounted to a backplate, and suited for isolation per EN/IEC 60947-2.

The 85 kA at 240 V AC matters for North American 208/240 V services — it clears a bolted fault at the main before the let-through energy damages branch devices. The 65 kA at 440 V and 50 kA at 500/525 V cover the higher-voltage distribution common in mining or marine installations. Category B utilization means it is listed for selectivity with other breakers in the same series.

Fixed mount to a backplate. Width 210 mm, height 327 mm, depth 147 mm — the depth is the dimension that determines gland-plate clearance in a shallow enclosure. Connection pitch is 70 mm, front-connected both upside and downside. IP40 enclosure rating, IK07 impact resistance. Power dissipation 15 W at rated current — account for that in the panel thermal budget.

Durability and thermal memory

Mechanical endurance is 10 000 cycles. Electrical endurance at full rated current: 2000 cycles at 690 V In, 4000 cycles at 690 V In/2, 5000 cycles at 440 V In, 6000 cycles at 440 V In/2. The MicroLogic 6.0 includes a 20-minute thermal memory — after a trip, it remembers the thermal state of the conductor for that window, preventing nuisance reclose on a still-hot circuit.