Schneider Electric C1047E040

Schneider Electric C1047E040 MicroLogic 7.2 E Trip Unit, 40

MPN C1047E040
Active

Schneider Electric ComPacT NSX series, MicroLogic 7.2 E electronic trip unit, 40 A at 40 °C, 4 poles, LSIR protection with integrated earth leakage, EN/IEC 60947-2.

$1,241.34 – $1,377.05 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C1047E040 specifications
ParameterValue
Display typeLCD display
Trip unit typeElectronic
Main product or component typeTrip unit
Voltage440 V AC 50/60 Hz
IP ratingIP40
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
ApplicationDistribution
Operating temperature-25...70 °C

Product details

Trip unit for ComPacT NSX — MicroLogic 7.2 E

The Schneider Electric C1047E040 is a MicroLogic 7.2 E electronic trip unit for the ComPacT NSX100...250 range. It's rated 40 A at 40 °C (Ir adjustable 18–40 A) and carries LSIR protection — long-time, short-time, instantaneous, and residual earth-leakage — all integrated into one 4-pole unit. The LCD display gives you local readout of metered values, event logs, and protection settings without needing a connected gateway. Built to EN/IEC 60947-2, this trip unit is designed for distribution boards where you need coordinated protection and energy metering in one package. The 20-minute thermal memory before and after tripping means the unit remembers the thermal state of the conductors even after a short interruption — useful when re-energizing a circuit that just tripped on overload.

L (long-time) protects against sustained overloads — Ir adjustable 18–40 A with tr delay from 15 s to 400 s at 1.5×Ir. S (short-time) handles bolted faults up to the Isd setting, with delay adjustable 0–0.4 s (I²t on or off). I (instantaneous) catches high-magnitude faults with no intentional delay. R (residual) is the integrated earth-leakage protection, Class A, switchable via the IΔn rotary. That means one trip unit covers overcurrent, short-circuit, and ground-fault protection without an external module. The 4P configuration supports multiple neutral protection modes: 3D + N/2 (half-rated neutral), 4D (full-rated), 3D + OSN (oversized neutral), or no neutral protection. Neutral position is left, fixed-mount only.

Integration notes

The trip unit snaps into the ComPacT NSX100–250 fixed-mount breaker. The LCD display and local signalling LEDs (green ready, red overload at 105% Ir, orange pre-alarm at 90% Ir) give you status at a glance without opening the door.