Skip to main content
Schneider Electric C10B44B100

C10B44B100 ComPacT NSX100B 100A MCCB, 25 kA at 415 V

MPN C10B44B100
Active

Schneider Electric ComPacT NSX NSX100B, 4P, 100 A, electronic trip unit MicroLogic 4.2 AB, breaking capacity 25 kA at 415 V AC, EN/IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C10B44B100 key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeEarth leakage circuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
Breaking capacity40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C

All specifications

C10B44B100 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth86 mm
Width140 mm
Height161 mm
Electrical life cycles50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Mechanical life cycles50000 cycles
ApplicationSpecial application
Operating temperature-25...70 °C

Product details

The C10B44B100: At 40 °C the trip unit is rated for 100 A continuous. That is the L (long-time) overload protection setting. The I protection is instantaneous for high faults. The integrated earth-leakage (R) protection means you don't need a separate add-on module — it's built into the trip unit, saving panel space and wiring. Breaking capacity varies with voltage: 40 kA Icu at 240 V AC, 25 kA at 415 V AC, 20 kA at 440 V AC, and 15 kA at 500 V AC. That prevents re-closing onto a still-hot circuit, which matters for motor or transformer loads that draw high inrush after a trip.

Mounts on a backplate (not DIN rail) in any orientation — horizontal, vertical, or flat on the back. Front connections top and bottom, with a 35 mm connection pitch. The 4-pole unit is 140 mm wide, 161 mm tall, 86 mm deep. IP40 enclosure protection and IK07 impact resistance. The toggle handle and the IΔn rotary switch give you a manual OFF for the earth-leakage function. Local signalling includes a flashing green LED for ready, a red LED for 105% Ir overload, and an orange LED for 90% Ir pre-alarm. Useful for a quick visual check during commissioning without opening the panel door.

MPN
C10B44B100