Schneider Electric C10B44B100 — Residual Current Breakers (RCCB/RCBO)

C10B44B100 ComPacT NSX100B 100A MCCB, 25 kA at 415 V

MPNC10B44B100
Active

Schneider Electric ComPacT NSX NSX100B, 4P, 100 A, electronic trip unit MicroLogic 4.2 AB, breaking capacity 25 kA at 415 V AC, EN/IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C10B44B100 — Residual Current Protection
ParameterValue
Earth-leakage protection class / typeClass A
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C10B44B100 — Electrical Ratings
ParameterValue
Rated current (In)100 A at 40 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Overvoltage categoryIV
Electrical durability50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Mechanical durability (operating cycles)50000 cycles
C10B44B100 — Identification
ParameterValue
Product nameComPacT NSX
Product / component typeEarth leakage circuit breaker
Product range / familyComPacT
Device short nameNSX100B
C10B44B100 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical Flat on the back
Control typeToggle
C10B44B100 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C10B44B100 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The C10B44B100: At 40 °C the trip unit is rated for 100 A continuous. That is the L (long-time) overload protection setting. The I protection is instantaneous for high faults. The integrated earth-leakage (R) protection means you don't need a separate add-on module — it's built into the trip unit, saving panel space and wiring. Breaking capacity varies with voltage: 40 kA Icu at 240 V AC, 25 kA at 415 V AC, 20 kA at 440 V AC, and 15 kA at 500 V AC. That prevents re-closing onto a still-hot circuit, which matters for motor or transformer loads that draw high inrush after a trip.

Mounts on a backplate (not DIN rail) in any orientation — horizontal, vertical, or flat on the back. Front connections top and bottom, with a 35 mm connection pitch. The 4-pole unit is 140 mm wide, 161 mm tall, 86 mm deep. IP40 enclosure protection and IK07 impact resistance. The toggle handle and the IΔn rotary switch give you a manual OFF for the earth-leakage function. Local signalling includes a flashing green LED for ready, a red LED for 105% Ir overload, and an orange LED for 90% Ir pre-alarm. Useful for a quick visual check during commissioning without opening the panel door.

Frequently asked questions

Where can I buy C10B44B100?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What standards does C10B44B100 comply with?

It complies with EN/IEC 60947-2. Pollution degree 3 per IEC 60664-1 and overvoltage category IV.

What is the breaking capacity of C10B44B100 at 415 V?

25 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2. It also carries 40 kA at 240 V, 20 kA at 440 V, and 15 kA at 500 V.

Does C10B44B100 have built-in earth-leakage protection?

Yes, the MicroLogic 4.2 AB trip unit has integrated earth-leakage protection (R function). No external add-on module needed.

MPN
C10B44B100