Skip to main content
Schneider Electric C10F2TM100

Schneider Electric C10F2TM100 ComPacT NSX100F 100A 2P MCCB,

MPN C10F2TM100
Active

Schneider Electric ComPacT NSX, NSX100F, circuit breaker, 100 A, 2P, thermal-magnetic TM-D trip unit, 18 kA Icu at 415 V AC, toggle control.

$175.68 – $196.72 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C10F2TM100 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz 500 V DC
Insulation voltage ui750 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity36 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380/415 V AC 50/60 Hz 1P conforming to IEC 60947-2 15 kA Icu at 440 V AC 50/60 Hz 1P conforming to IEC 60947-2 10 kA Icu at 500/525 V AC 50/60 Hz 2P conforming to IEC 60947-2 5 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 250 V DC 50/60 Hz 1 pole conforming to IEC 60947-2 36 kA Icu at 500 V DC 50/60 Hz 2 poles in series conforming to IEC 60947-2
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C

All specifications

C10F2TM100 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth86 mm
Width70 mm
Height161 mm
Electrical life cycles20000 cycles at 277 V In/2 10000 cycles at 277 V In
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

Breaking capacity and selectivity — what the ratings mean

The C10F2TM100: The F breaking capacity code means 18 kA Icu at 380/415 V AC, 1-pole tested per IEC 60947-2. The thermal-magnetic TM-D trip provides fixed L (overload) and I (short-circuit) protection curves — no interchangeable rating plugs, so the 100 A frame is the setting.

Mounting and integration into a panel

Fixed-mount on a backplate, with front-facing line and load terminals. The 70 mm width and 161 mm height fit standard distribution panel cutouts; depth is 86 mm including the toggle. IP40 front face, IK07 impact resistance.

MPN
C10F2TM100