Schneider Electric C10H47E040 ComPacT NSX 40A, 100kA at 240V

MPN C10H47E040
Active

Schneider Electric ComPacT NSX, NSX100H, circuit breaker, 40 A at 40 °C, MicroLogic 7.2 E trip unit, 4P, 100 kA Icu at 240 V AC, EN/IEC 60947-2.

$1,634.18 – $3,652.02 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C10H47E040 key specifications
ParameterValue
Control typeToggle
Display typeLCD display
Trip unit typeElectronic
Main product or component typeEarth leakage circuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-40 °C

All specifications

C10H47E040 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degreeclass 3
Depth86 mm
Width140 mm
Height161 mm
Electrical life cycles50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Mechanical life cycles50000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

ComPacT NSX100H with MicroLogic 7.2 E — 40 A, 4P, 100 kA

The Schneider Electric C10H47E040 is a ComPacT NSX100H molded-case circuit breaker with a MicroLogic 7.2 E electronic trip unit, rated 40 A at 40 °C. It is a 4-pole unit (4P) with a breaking capacity of 100 kA Icu at 240 V AC, 70 kA at 415 V, and 65 kA at 480 V, all per IEC 60947-2. The electronic trip unit provides L (long-time overload), S (short-time short-circuit), I (instantaneous), and R (earth-leakage) protection — configurable selectivity for a coordinated distribution system. Mounts on a backplate (mounting support: backplate) in horizontal or vertical orientation, flat on the back. Front connections on both upside and downside simplify bus-bar or cable routing in a panel. The toggle control and LCD display give local status and metering readout without opening the door.

At 415 V (common in European industrial grids) it still holds 70 kA, and at 480 V (North American common) it delivers 65 kA. That puts this in the high-interrupting class for a 40 A frame, giving headroom for most distribution panels without needing upstream fuses. The MicroLogic 7.2 E trip unit is electronic, not thermal-magnetic, so it offers adjustable long-time pickup and delay (L), short-time pickup and delay (S), instantaneous pickup (I), and earth-leakage (R) protection. Overvoltage category IV means it's suitable for the main distribution point (utility entrance or main switchboard), not just downstream sub-panels.

Integration notes

Dimensions: 161 mm height, 140 mm width, 86 mm depth. The 35 mm connection pitch matches standard bus-bar spacing for panelboard integration. Five accessory slots allow adding auxiliary contacts, shunt trips, or communication modules without removing the breaker from the panel. The LCD display provides time-stamped event histories, energy metering, demand current and power values, and maintenance indicators — useful for a facility engineer tracking load profiles without a separate power meter.

MPN