Skip to main content
Schneider Electric C10N3MA050

Schneider Electric C10N3MA050 ComPacT NSX 50A MCCB, 3P, 90kA

MPN C10N3MA050
Active

Schneider Electric ComPacT NSX, NSX100N frame, 50 A magnetic-only MA trip unit, 3-pole, 90 kA Icu at 240 V AC, EN/IEC 60947-2.

$216.93 – $490.54 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C10N3MA050 key specifications
ParameterValue
Control typeToggle
Trip unit typeMagnetic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C

All specifications

C10N3MA050 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth86 mm
Width105 mm
Height161 mm
Electrical life cycles50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Mechanical life cycles50000 cycles
ApplicationMotor protection
Operating temperature-25...70 °C

Product details

ComPacT NSX 50 A MCCB — magnetic-only motor protection

It is designed specifically for motor protection, providing short-circuit (magnetic) protection only — no thermal overload element, so a separate motor starter or overload relay handles the thermal curve. The 50 A rating holds at 65 °C ambient, which is the standard temperature for panel derating; no further temperature correction is needed up to that point. Breaking capacity follows the N class: 90 kA Icu at 240 V AC, 50 kA at 480 V AC, and 10 kA at 600 V AC per UL 60947-4-1; IEC 60947-2 ratings run 50 kA at 415 V, 36 kA at 500 V, and 10 kA at 690 V. The IEC utilisation category is A — not intended for selectivity with downstream breakers on the same fault, but fine for radial motor feeds where coordination is handled upstream.

Mounting, dimensions, and environment

Mounts on a backplate — no DIN-rail adapter, so plan for drilled panel or a sub-plate. Dimensions are 161 mm H × 105 mm W × 86 mm D, with a 35 mm connection pitch between poles. Operating altitude 0–2000 m without derating, 2000–5000 m with derating — no issue for most plant-floor installations.

MPN
C10N3MA050