Skip to main content
Schneider Electric C10N44V100

Schneider C10N44V100 ComPacT NSX100N MCCB, 100 A, 50 kA

MPN C10N44V100
Active

Schneider Electric ComPacT NSX NSX100N, 4P MCCB, 100 A, 50 kA Icu at 415 V AC, MicroLogic 4.2 electronic trip unit with integrated earth-leakage protection.

$1,148.69 – $2,155.14 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C10N44V100 key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeEarth leakage circuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
Breaking capacity90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 50 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 10 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C

All specifications

C10N44V100 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth86 mm
Width140 mm
Height161 mm
Electrical life cycles50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Mechanical life cycles50000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric C10N44V100 is a ComPacT NSX100N 4-pole moulded-case circuit breaker with a MicroLogic 4.2 electronic trip unit, rated 100 A at 40 °C. The MicroLogic 4.2 provides L (long-time overload), So (short-time short-circuit with fixed delay), I (instantaneous short-circuit), and R (earth-leakage) protection — all in one electronic trip unit. The earth-leakage is integrated, so you don't need a separate RCCB or add-on module; it monitors residual current directly through the breaker.

Mounting and integration into a panel

Mounts on a backplate in horizontal or vertical orientation, flat on the back. The 4-pole form factor with neutral on the left takes 140 mm width, 161 mm height, and 86 mm depth — measure your enclosure depth before committing; 86 mm is shallow enough for most 200 mm deep enclosures but check the gland plate clearance if you're running cables front-entry (both upside and downside connections are front). The 35 mm connection pitch matches standard busbar systems.

Pollution degree 3 (conforming to IEC 60664-1) means it's rated for conductive pollution environments typical of industrial control panels — not just clean office switchgear. Overvoltage category IV covers the main distribution point. The electrical durability figures (50,000 cycles at 440 V In/2, 30,000 at 440 V In) give you a realistic service life for frequent switching applications like capacitor banks or large motor starters.