Specifications

C10R36M025 key specifications
ParameterValue
Control typeToggle
Display typeLCD display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz
Breaking capacity200 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 200 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 200 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 80 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 45 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C

All specifications

C10R36M025 additional specifications
ParameterValue
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degreeclass 3
Depth86 mm
Width105 mm
Height161 mm
Electrical life cycles20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical life cycles20000 cycles
ApplicationMotor protection
Operating temperature-25...70 °C

Product details

Overview

The C10R36M025 is a Schneider ComPacT NSX molded case circuit breaker rated 25 A with a 200 kA breaking capacity at 690 V AC, built for motor protection duty with a MicroLogic 6.2 E-M electronic trip unit. It is a 3-pole fixed-mount unit with a toggle control, an LCD display, and an energy meter, meeting EN/IEC 60947-2 with Class II insulation on the front face.

Compared to the distribution-oriented C10F3TM025, the C10R36M025 delivers a 200 kA breaking capacity versus 85 kA, and its MicroLogic 6.2 E-M trip unit provides adjustable long-time, short-time, instantaneous, and ground-fault protection tailored for motor starting curves.

MPN