Schneider Electric C10R36M025 — Residual Current Breakers (RCCB/RCBO)

Schneider C10R36M025 ComPacT NSX MCCB, 25 A, 200 kA, motor protection

MPNC10R36M025
Active

Schneider C10R36M025 Compact Nsx, New Generation — now discontinued, supplied from remaining surplus and broker stock.

$2,050.12Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jun 2026

Specifications

C10R36M025 — Residual Current Protection
ParameterValue
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 95 % Ith (red) for temperature over set point
C10R36M025 — Electrical Ratings
ParameterValue
Rated current (In)25 A at 65 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz
Poles description3P
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Overvoltage categoryIII
Electrical durability20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (operating cycles)20000 cycles
C10R36M025 — Identification
ParameterValue
Product nameComPacT NSX
Product / component typeCircuit breaker
Product range / familyComPacT
Device short nameNSX100R
C10R36M025 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical Flat on the back
Control typeToggle
C10R36M025 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C10R36M025 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

Overview

The C10R36M025 is a Schneider ComPacT NSX molded case circuit breaker rated 25 A with a 200 kA breaking capacity at 690 V AC, built for motor protection duty with a MicroLogic 6.2 E-M electronic trip unit. It is a 3-pole fixed-mount unit with a toggle control, an LCD display, and an energy meter, meeting EN/IEC 60947-2 with Class II insulation on the front face.