Skip to main content
Schneider Electric C10R46E040

Schneider Electric C10R46E040 ComPacT NSX 40A, 200kA 415V

MPN C10R46E040
Active

Schneider Electric, ComPacT NSX, MCCB, C10R46E040, 40 A, 200 kA Icu at 415 V AC, MicroLogic 6.2 E, 4P.

$26.86 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C10R46E040 key specifications
ParameterValue
Control typeToggle
Display typeLCD display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz
Breaking capacity200 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 200 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 200 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 80 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 45 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C

All specifications

C10R46E040 additional specifications
ParameterValue
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degreeclass 3
Depth86 mm
Width140 mm
Height161 mm
Electrical life cycles20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The C10R46E040 is a ComPacT NSX100R frame MCCB with a MicroLogic 6.2 E electronic trip unit, rated 40 A at 40 °C. The 4-pole (4P) configuration with neutral on the left handles three-phase plus neutral distribution panels — common in commercial and industrial switchboards.

Protection and metering built in

The MicroLogic 6.2 E trip unit provides L (long-time overload), S (short-time short-circuit), I (instantaneous short-circuit), and G (ground-fault) protection — all adjustable via the front LCD display and toggle controls. That's a full selective-coordination package: the S setting lets you delay tripping so a downstream breaker clears a fault first, keeping this breaker closed for upstream loads. The electronic trip also includes an energy meter function, logging instantaneous and demand values, time-stamped events, power quality data, and maintenance indicators.

Mounting and environment

Mounts on a backplate in horizontal or vertical orientation, flat against the panel. Front connections on both upside and downside make busbar and cable routing straightforward in a switchboard. The 35 mm connection pitch matches standard DIN-rail terminal spacing for auxiliary wiring. IK07 impact rating (IEC 62262) handles accidental tool drops during maintenance.

MPN
C10R46E040