Schneider Electric C10R46E040 ComPacT NSX 40A, 200kA 415V

MPNC10R46E040
Active

Schneider Electric, ComPacT NSX, MCCB, C10R46E040, 40 A, 200 kA Icu at 415 V AC, MicroLogic 6.2 E, 4P.

$26.86Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C10R46E040 — Residual Current Protection
ParameterValue
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C10R46E040 — Electrical Ratings
ParameterValue
Rated current (In)40 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Overvoltage categoryIII
Electrical durability20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (operating cycles)20000 cycles
C10R46E040 — Identification
ParameterValue
Product nameComPacT NSX
Product / component typeCircuit breaker
Product range / familyComPacT
Device short nameNSX100R
C10R46E040 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical Flat on the back
Control typeToggle
C10R46E040 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C10R46E040 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The C10R46E040 is a ComPacT NSX100R frame MCCB with a MicroLogic 6.2 E electronic trip unit, rated 40 A at 40 °C. The 4-pole (4P) configuration with neutral on the left handles three-phase plus neutral distribution panels — common in commercial and industrial switchboards.

Protection and metering built in

The MicroLogic 6.2 E trip unit provides L (long-time overload), S (short-time short-circuit), I (instantaneous short-circuit), and G (ground-fault) protection — all adjustable via the front LCD display and toggle controls. That's a full selective-coordination package: the S setting lets you delay tripping so a downstream breaker clears a fault first, keeping this breaker closed for upstream loads. The electronic trip also includes an energy meter function, logging instantaneous and demand values, time-stamped events, power quality data, and maintenance indicators.

Mounting and environment

Mounts on a backplate in horizontal or vertical orientation, flat against the panel. Front connections on both upside and downside make busbar and cable routing straightforward in a switchboard. The 35 mm connection pitch matches standard DIN-rail terminal spacing for auxiliary wiring. IK07 impact rating (IEC 62262) handles accidental tool drops during maintenance.

Frequently asked questions

What is C10R46E040's breaking capacity at 415 V?

200 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2.

What protection functions does the MicroLogic 6.2 E trip unit provide?

L (long-time overload), S (short-time short-circuit), I (instantaneous short-circuit), and G (ground-fault) protection.

Where can I buy C10R46E040?

Sourced and quoted to order against an RFQ through independent distribution — availability and current pricing confirmed at quote time.