Skip to main content
Schneider Electric C10R46E100

C10R46E100 ComPacT NSX 100A 4P 200kA MCCB, MicroLogic 6.2 E

MPN C10R46E100
Active

Schneider Electric ComPacT NSX, NSX100R, MCCB, 100 A at 40 °C, 4P, 200 kA Icu at 415 V AC, MicroLogic 6.2 E electronic trip unit, LSIG protection, toggle control, LCD display.

$27.11 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C10R46E100 key specifications
ParameterValue
Control typeToggle
Display typeLCD display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-40 °C

All specifications

C10R46E100 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degreeclass 3
Depth86 mm
Width140 mm
Height161 mm
Electrical life cycles20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

MCCB with MicroLogic 6.2 E — 100 A, 200 kA, LSIG

The C10R46E100 is a Schneider Electric ComPacT NSX100R moulded-case circuit breaker rated 100 A at 40 °C, 4 poles, with a MicroLogic 6.2 E electronic trip unit providing LSIG protection — overload (L), short-time short-circuit (S), instantaneous (I), and ground-fault (G). Its breaking capacity hits 200 kA Icu at 415 V AC 50/60 Hz per IEC 60947-2, which means it can safely interrupt fault currents up to that level without cascading upstream — critical for high-fault panels near large transformers or generators. The electronic trip unit logs time-stamped events, demand values, energy metering, and power quality data, displayed on the integrated LCD.

At 690 V AC the Icu drops to 45 kA, still enough for most industrial step-down transformers.

Mounts on a backplate in horizontal or vertical orientation, flat on the back. Front connections on both upside and downside simplify bus-bar and cable routing in a panel. The 35 mm connection pitch matches standard DIN-rail terminal blocks for auxiliary wiring.

MPN