Schneider Electric C10V46E040

Schneider Electric C10V46E040 ComPacT NSX, 40 A, 85 kA Icu

MPN C10V46E040
Active

Schneider Electric ComPacT NSX, 4-pole MCCB, 40 A, MicroLogic 6.2 E electronic trip unit, 85 kA Icu at 500 V AC, LSI+G protection.

$15.26 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C10V46E040 key specifications
ParameterValue
Control typeToggle
Display typeLCD display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz
Breaking capacity85 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 80 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 75 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C

All specifications

C10V46E040 additional specifications
ParameterValue
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degreeclass 3
Depth86 mm
Width140 mm
Height161 mm
Electrical life cycles20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The trip unit gives you LSI+G protection — overload (long-time), short-time short-circuit, instantaneous short-circuit, and ground fault — all adjustable from the front LCD display. That's a serious interrupting rating for a 40 A frame — it lets you use this breaker downstream of a high-capacity transformer without worrying about cascading failure. At 690 V AC it still holds 75 kA Icu, which is rare for a compact frame. The 20-minute thermal memory before and after tripping is a detail that matters on motor circuits or feeders with repetitive overloads. The trip unit remembers the thermal history of the last event, so a second overload close on the heels of the first will trip faster — protects the cable insulation, not just the breaker rating.

The MicroLogic 6.2 E trip unit is a communicating electronic trip with energy metering capability. If your BOM calls for this specific trip unit, there isn't a drop-in pin-compatible alternative — the 6.2 E is the only one with ground-fault protection and energy metering in this frame. The standard 2.2 or 5.2 trip units won't give you the G (ground-fault) function or the energy measurement.

The 4-pole version is 140 mm wide, 161 mm tall, 86 mm deep. Connection pitch is 35 mm, front-connected both top and bottom. Neutral is on the left. That's a standard footprint for a 160 A frame MCCB, so it fits existing panel cutouts and busbar layouts in most distribution boards.

Durability and endurance

Electrical durability varies with load: 20,000 cycles at 440 V at half rated current, 10,000 cycles at full 40 A, and 5,000 cycles at 690 V full load. That's typical for a 160 A frame electronic-trip MCCB — the mechanical life is the limiting factor, not the contacts.

MPN
C10V46E040