Schneider Electric C11F34V025L

Schneider Electric C11F34V025L ComPacT NSXm MCCB, 25 A, 36 k

MPN C11F34V025L
Active

Schneider Electric ComPacT NSXm, C11F34V025L, 3P MCCB with MicroLogic 4.1 electronic trip unit, 25 A at 40 °C, 36 kA at 415 V AC, integrated earth-leakage protection.

$762.36 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C11F34V025L key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeEarth leakage circuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
IP ratingIP40
Terminal pitch35 mm with spreaders 27 mm without spreaders
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

C11F34V025L additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degreeclass 3
ColorGrey (RAL 7016)
Depth80 mm
Width108 mm
Height144 mm
Electrical life cycles20000 cycles at 440 V In/2 10000 cycles at 440 V In
Mechanical life cycles20000 cycles
ApplicationDistribution
Safety categoryF 36 kA 415 V AC
Operating temperature-25...70 °C

Product details

The Schneider Electric C11F34V025L is a ComPacT NSXm 3-pole moulded-case circuit breaker with a MicroLogic 4.1 electronic trip unit, rated 25 A at 40 °C and carrying a 36 kA breaking capacity at 415 V AC — F performance level. It is an earth-leakage circuit breaker with integrated earth-leakage protection, configurable for sensitivities from 30 mA to 5 A for both class A and class AC residual currents.

Category A utilisation means it is not intended for current-limiting coordination with downstream breakers in a fully selective scheme — treat it as the main or branch breaker where full selectivity is not the primary design goal. The EN/IEC 60947-2 standard it complies with covers the mechanical and electrical endurance, dielectric, and temperature-rise requirements for industrial application.

The 9-module pitch at 108 mm wide, 144 mm high, 80 mm deep fits standard enclosure cutouts. The 35 mm connection pitch with spreaders (27 mm without) matches common busbar and cable-lug spacing. IP40 front face with IK07 impact resistance is fine for dry indoor panels; not rated for washdown environments.