Schneider Electric C11H34V050B

Schneider Electric C11H34V050B ComPacT NSXm MCCB, 50 A, 70 k

MPN C11H34V050B
Active

Schneider Electric ComPacT NSXm, C11H34V050B, 3-pole MCCB, 50 A at 40 °C, 70 kA at 415 V AC, MicroLogic 4.1 electronic trip unit, integrated earth-leakage.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C11H34V050B key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeEarth leakage circuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
IP ratingIP40
Terminal pitch35 mm with spreaders 27 mm without spreaders
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

C11H34V050B additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degreeclass 3
ColorGrey (RAL 7016)
Depth80 mm
Width108 mm
Height144 mm
Electrical life cycles20000 cycles at 440 V In/2 10000 cycles at 440 V In
Mechanical life cycles20000 cycles
ApplicationDistribution
Safety categoryH 70 kA 415 V AC
Operating temperature-25...70 °C

Product details

The Schneider Electric C11H34V050B is a ComPacT NSXm moulded-case circuit breaker with 3 poles, rated 50 A at 40 °C and a 70 kA interrupting capacity at 415 V AC — the H performance level. It carries a MicroLogic 4.1 electronic trip unit with integrated earth-leakage protection, adjustable from 30 mA to 5 A in class A or AC sensitivity. Built to EN/IEC 60947-2, it is a distribution-grade MCCB for panelboards, switchboards, and sub-distribution in commercial or light industrial sites.

The MicroLogic 4.1 is a fixed-curve electronic trip unit — no field-adjustable long-time or short-time pickup, but it includes thermal memory that remembers the last 20 minutes of heating before and after a trip, preventing nuisance reclosure on a hot cable. Integrated earth-leakage protection means this single device covers both overcurrent and ground-fault in one package — no separate RCCB or RCBO needed. Sensitivity choices cover 30 mA (personnel protection) up to 5 A (equipment protection), selectable by the installer.

Mounting and integration notes

Mounts on a backplate in horizontal or vertical orientation — flat on the back. The 9-module pitch (108 mm wide, 144 mm high, 80 mm deep) fits standard 35 mm DIN-rail enclosures with spreaders; without spreaders the connection pitch is 27 mm. Front connections top and bottom accept compression lugs or busbars. IP40 front face, IK07 impact resistance — suitable for enclosed panel installation, not for washdown areas.

MPN