Schneider Electric ComPacT NSXm, C11H34V050L, earth leakage circuit breaker, 3P, 50 A, MicroLogic 4.1 electronic trip unit, H 70 kA 415 V AC, EN/IEC 60947-2.

$793.85 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C11H34V050L key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeEarth leakage circuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
IP ratingIP40
Terminal pitch35 mm with spreaders 27 mm without spreaders
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

C11H34V050L additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degreeclass 3
ColorGrey (RAL 7016)
Depth80 mm
Width108 mm
Height144 mm
Electrical life cycles20000 cycles at 440 V In/2 10000 cycles at 440 V In
Mechanical life cycles20000 cycles
ApplicationDistribution
Safety categoryH 70 kA 415 V AC
Operating temperature-25...70 °C

Product details

The Schneider Electric C11H34V050L is a ComPacT NSXm earth leakage circuit breaker, 3-pole, rated 50 A at 40 °C with a MicroLogic 4.1 electronic trip unit.

Push the ambient higher and you derate — the electronic trip unit compensates, but the frame and terminal limits still apply. The MicroLogic 4.1 is an electronic trip unit with integrated earth-leakage protection, adjustable sensitivity from 30 mA up to 5 A for class AC and 30 mA to 1 A for class A. That means you can set it to catch ground faults on a motor feeder or a lighting circuit without adding a separate RCD block. The 70 kA figure is the Icu (ultimate short-circuit breaking capacity) per EN/IEC 60947-2, Category A. That standard also governs the overvoltage category IV rating, meaning it's rated for installation at the origin of the installation, not just downstream sub-distribution.

The 9-module pitch (9 x 9 mm = 81 mm) plus the 108 mm width and 144 mm height fits standard distribution board cutouts. Connection is front-facing on both sides, with Everlink terminals accepting 2.5 to 95 mm² rigid or stranded aluminium/copper on the line side and 2.5 to 70 mm² fine-stranded copper on the load side. The connection pitch is 35 mm with spreaders, 27 mm without — that matters when you're laying out busbars or cable lugs in a tight enclosure. That's typical for an industrial panel environment.