Skip to main content
Schneider Electric C160H32EFM

Schneider Electric C160H32EFM ComPacT NS MCCB, 1600 A, 70 kA

MPN C160H32EFM
Active

Schneider Electric ComPacT NS new generation, C160H32EFM, 3P fixed MCCB, 1600 A at 50 °C, 70 kA Icu at 415 V AC, MicroLogic 2.0 E electronic trip unit, LSI protection.

$3,484.81 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C160H32EFM key specifications
ParameterValue
Control typeManually operated
Display typeLCD display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Utilization categoryCategory B
IP ratingIP40
Terminal pitch70 mm
Connection surface topFront

All specifications

C160H32EFM additional specifications
ParameterValue
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947
Depth147 mm
Width210 mm
Height327 mm
Electrical life cycles1000 cycles at 690 V In 2000 cycles at 690 V In/2 2000 cycles at 440 V In 5000 cycles at 440 V In/2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The C160H32EFM is a 3-pole fixed-mount ComPacT NS new generation MCCB rated 1600 A at 50 °C, carrying a MicroLogic 2.0 E electronic trip unit with L (long-time overload) and I (instantaneous short-circuit) protection curves. The 74 W power loss at rated current matters for enclosure thermal budgeting; plan ventilation accordingly. The 1600 A frame covers main incoming feeders or large bus risers in industrial and commercial switchboards. Fixed mounting on a backplate with front connections top and bottom keeps the wiring pattern predictable for panel builders.

The 85 kA Icu at 240 V and 70 kA at 415 V give the C160H32EFM headroom for high-available-fault installations. The 65 kA at 440 V and 50 kA at 500/525 V still cover most industrial service entrances. At 660/690 V it holds 42 kA — useful for 600 V class systems. These ratings conform to IEC 60947-2 Category B, meaning the breaker is fully selective with downstream devices under short-circuit conditions. The MicroLogic 2.0 E trip unit provides LSI protection via electronic sensing. Thermal memory holds for 20 minutes after a trip, preventing immediate reclose on a still-hot conductor. The LCD display shows measured values and fault type, and the four red LEDs indicate the fault cause — overload, short-circuit, or ground fault (though this unit ships without earth-leakage protection).

Fixed mounting on a backplate with 70 mm connection pitch. Front connections both top and bottom. Dimensions: 327 mm high, 210 mm wide, 147 mm deep. IK07 impact resistance handles incidental contact in a panel. Manually operated with an LCD display for local metering and energy measurement. The electronic trip unit draws power from the line side — no auxiliary supply needed for basic protection.

MPN
C160H32EFM