Schneider Electric C160H35AFM

Schneider Electric C160H35AFM ComPacT NS, 1600 A, 85 kA

MPN C160H35AFM
Active

Schneider Electric, ComPacT NS new generation, C160H35AFM, 3P 1600 A MCCB, 85 kA Icu at 240 V AC, MicroLogic 5.0 A electronic trip unit, fixed mount, IP40.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C160H35AFM key specifications
ParameterValue
Control typeManually operated
Display typeLCD display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Utilization categoryCategory B
IP ratingIP40
Terminal pitch70 mm
Connection surface topFront
Connection surface bottomFront

All specifications

C160H35AFM additional specifications
ParameterValue
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947
Depth147 mm
Width210 mm
Height327 mm
Electrical life cycles1000 cycles at 690 V In 2000 cycles at 690 V In/2 2000 cycles at 440 V In 5000 cycles at 440 V In/2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric C160H35AFM is a ComPacT NS new generation 3-pole MCCB, rated 1600 A at 50 °C with a MicroLogic 5.0 A electronic trip unit. It carries an 85 kA Icu breaking capacity at 240 V AC, 70 kA at 415 V AC, and 42 kA at 690 V AC per IEC 60947-2 — that 70 kA at 415 V is the H-code rating you see on the nameplate. The trip unit provides L (long-time overload), S (short-time short-circuit), and I (instantaneous) protection curves, all adjustable through the LCD display. This is a manually operated, fixed-mount breaker designed for distribution duty, not motor-starting cycles.

The 1600 A frame at 50 °C is the continuous current rating — no derating needed at that ambient, but above 50 °C you follow the curve in the manual.

Integration notes

Fixed-mount, backplate-supported — no DIN-rail adapter. The 210 mm width, 327 mm height, and 147 mm depth fit a standard distribution section; connection pitch is 70 mm. The LCD display and four red fault LEDs plus one yellow overload LED give local diagnostics without opening the door. Mechanical durability is 10,000 cycles; electrical durability varies by voltage and current — 1,000 cycles at 690 V In, 2,000 at 690 V In/2, 2,000 at 440 V In, 5,000 at 440 V In/2.

IK07 impact resistance per EN 50102. IP40 per IEC 60529. Operating altitude up to 2,000 m without derating, 2,000–5,000 m with derating. Relative humidity 0–95 %. No earth-leakage protection built in — that's a separate accessory or upstream device.

MPN
C160H35AFM