Schneider Electric C160H360FM

Schneider Electric C160H360FM ComPacT NS, 1600 A, 70 kA 415

MPN C160H360FM
Active

Schneider Electric ComPacT NS new generation, C160H360FM, 3P 1600 A circuit breaker, MicroLogic 6.0 electronic trip unit, 70 kA Icu at 415 V AC, fixed mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C160H360FM key specifications
ParameterValue
Control typeManually operated
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Utilization categoryCategory B
IP ratingIP40
Terminal pitch70 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C

All specifications

C160H360FM additional specifications
ParameterValue
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degree3 conforming to IEC 60947
Depth147 mm
Width210 mm
Height327 mm
Electrical life cycles1000 cycles at 690 V In 2000 cycles at 690 V In/2 2000 cycles at 440 V In 5000 cycles at 440 V In/2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric C160H360FM is a ComPacT NS new generation 3-pole fixed-mount circuit breaker with a MicroLogic 6.0 electronic trip unit rated at 1600 A at 50 °C. The breaker is part of the ComPacT NS630b…1600 new generation range. Breaking capacity is 85 kA Icu at 220/240 V AC, 70 kA Icu at 380/415 V AC, 65 kA Icu at 440 V AC, 50 kA Icu at 500/525 V AC, and 42 kA Icu at 660/690 V AC — all at 50/60 Hz per IEC 60947-2. The MicroLogic 6.0 trip unit provides L (long-time overload), S (short-time short-circuit), I (instantaneous short-circuit), and G (ground-fault) protection curves — all electronic, adjustable. The thermal memory is 20 minutes, so the trip unit remembers prior heating events and shortens the time-to-trip on a reclose, which matters for motor or transformer inrush that can follow a fast reclosure. Power losses are 74 W at rated current — that heat has to leave the enclosure. The breaker is IP40 (finger-safe, no water ingress) and IK07 (2 J impact resistance), so it is suited for indoor switchboard or panel mounting on a backplate. Front connections top and bottom, 70 mm phase pitch, so it fits standard busbar and cable layouts.

Integration and deployment

Mounting is fixed on a backplate — no DIN-rail adapter, so plan for a drilled or tapped panel. Dimensions are 327 mm high × 210 mm wide × 147 mm deep, which is a standard ComPacT NS footprint. The 70 mm phase pitch matches the existing busbar systems in most LV switchboards. Front connections top and bottom simplify busbar routing and cable glanding. Local signalling uses four red LEDs for fault indication (one each for L, S, I, G trip events) and one yellow LED for overload pre-alarm — useful for a technician walking the panel to identify which protection curve caused the trip without plugging in a laptop. Relative humidity range is 0–95 %. These environmental ratings mean it is fit for industrial switchrooms, not just climate-controlled data centres.

MPN
C160H360FM