Skip to main content
Schneider Electric C160N32EFM

C160N32EFM ComPacT NS 1600A 3P MCCB, 85 kA at 240 V

MPN C160N32EFM
Active

Schneider Electric ComPacT NS new generation, C160N32EFM, 3-pole 1600 A MCCB with MicroLogic 2.0 E electronic trip unit, 85 kA Icu at 240 V AC, fixed mount, front connections.

$2,909.89 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C160N32EFM key specifications
ParameterValue
Control typeManually operated
Display typeLCD display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Utilization categoryCategory B
IP ratingIP40
Terminal pitch70 mm
Connection surface topFront
Connection surface bottomFront

All specifications

C160N32EFM additional specifications
ParameterValue
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947
Depth147 mm
Width210 mm
Height327 mm
Electrical life cycles1000 cycles at 690 V In 2000 cycles at 690 V In/2 2000 cycles at 440 V In 5000 cycles at 440 V In/2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric C160N32EFM is a ComPacT NS new generation 3-pole molded-case circuit breaker rated 1600 A at 50 °C, fitted with a MicroLogic 2.0 E electronic trip unit. The 2.0 E provides L (long-time overload) and I (instantaneous short-circuit) protection curves, plus an integrated energy meter — so it serves both as a main distribution breaker and a metering point in one enclosure. The 85 kA Icu at 240 V AC (50 kA at 415 V AC) means it can interrupt fault currents up to that level without upstream fuses or a current-limiting reactor, per IEC 60947-2 Category B utilization. That breaking capacity code is N — the standard interrupting rating for this frame size, not the high-performance S or H tier. The trip unit's electronic design includes a 20-minute thermal memory, which prevents nuisance reclosing after a sustained overload by retaining the thermal model of the protected conductor. For a 1600 A distribution feeder feeding downstream panelboards or large motor control centers, that memory matters — it avoids re-energizing a circuit that hasn't fully cooled. The LCD display on the front face shows real-time current, energy, and trip-event data without needing a separate power meter or communication gateway.

Mounting and integration — fixed backplate, front connections

Fixed-mount design on a backplate with front upside and downside connections and a 70 mm connection pitch. That pitch matches standard busbar systems for switchboard builders — no adapter plates needed for common distribution panels. The 210 mm width and 327 mm height fit a standard 600 mm wide enclosure section with room for cable entry on both sides. Four red LEDs for fault indication and one yellow LED for overload give immediate visual status without opening the door. The manually operated rotary handle provides clear ON/OFF position indication and padlockable in the OFF position per standard safety lockout procedures.

Overvoltage category III suits fixed-installation distribution boards downstream of the service entrance.

MPN