Schneider Electric C160N32EFM — Miniature Circuit Breakers (MCB)

C160N32EFM ComPacT NS 1600A 3P MCCB, 85 kA at 240 V

MPNC160N32EFM
Active

Schneider Electric ComPacT NS new generation, C160N32EFM, 3-pole 1600 A MCCB with MicroLogic 2.0 E electronic trip unit, 85 kA Icu at 240 V AC, fixed mount, front connections.

$2,909.89Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

C160N32EFM — Identification
ParameterValue
Product nameComPacT NS new generation
Product rangeComPacT
Product range (series)ComPacT NS630b...1600 new generation
Product/component typeCircuit breaker
Device applicationDistribution
C160N32EFM — Ratings
ParameterValue
Rated current (In)1600 A at 50 °C
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)37 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 37 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 37 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)8 kV conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory B
Overvoltage categoryIII
C160N32EFM — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)1000 cycles at 690 V In 2000 cycles at 690 V In/2 2000 cycles at 440 V In 5000 cycles at 440 V In/2
Mechanical durability (cycles)10000 cycles
C160N32EFM — Mechanical
ParameterValue
Mounting supportBackplate
Mounting modeFixed
Control typeManually operated
Local signalling/indication4 LEDs (red) for fault indication 1 LED (yellow) for overload
C160N32EFM — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947
Relative humidity0...95 %
C160N32EFM — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C160N32EFM — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.4...1 x In
Trip unit protection functionsLI

Product details

The Schneider Electric C160N32EFM is a ComPacT NS new generation 3-pole molded-case circuit breaker rated 1600 A at 50 °C, fitted with a MicroLogic 2.0 E electronic trip unit. The 2.0 E provides L (long-time overload) and I (instantaneous short-circuit) protection curves, plus an integrated energy meter — so it serves both as a main distribution breaker and a metering point in one enclosure. The 85 kA Icu at 240 V AC (50 kA at 415 V AC) means it can interrupt fault currents up to that level without upstream fuses or a current-limiting reactor, per IEC 60947-2 Category B utilization. That breaking capacity code is N — the standard interrupting rating for this frame size, not the high-performance S or H tier. The trip unit's electronic design includes a 20-minute thermal memory, which prevents nuisance reclosing after a sustained overload by retaining the thermal model of the protected conductor. For a 1600 A distribution feeder feeding downstream panelboards or large motor control centers, that memory matters — it avoids re-energizing a circuit that hasn't fully cooled. The LCD display on the front face shows real-time current, energy, and trip-event data without needing a separate power meter or communication gateway.

Mounting and integration — fixed backplate, front connections

Fixed-mount design on a backplate with front upside and downside connections and a 70 mm connection pitch. That pitch matches standard busbar systems for switchboard builders — no adapter plates needed for common distribution panels. The 210 mm width and 327 mm height fit a standard 600 mm wide enclosure section with room for cable entry on both sides. Four red LEDs for fault indication and one yellow LED for overload give immediate visual status without opening the door. The manually operated rotary handle provides clear ON/OFF position indication and padlockable in the OFF position per standard safety lockout procedures.

Overvoltage category III suits fixed-installation distribution boards downstream of the service entrance.

Frequently asked questions

What is the breaking capacity of C160N32EFM at 415 V?

50 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2, which is the N breaking capacity code for this frame.

What protection curves does the MicroLogic 2.0 E trip unit provide?

L (long-time overload protection) and I (instantaneous short-circuit protection), with a 20-minute thermal memory.

MPN
C160N32EFM