Schneider Electric C160N42AFM

Schneider Electric C160N42AFM ComPacT NS 1600A, 4P, 50kA 415

MPN C160N42AFM
Active

Schneider Electric ComPacT NS new generation, C160N42AFM, 4-pole MCCB, 1600 A at 50 °C, MicroLogic 2.0 A electronic trip unit, 50 kA Icu at 415 V AC, fixed mount, front connection.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C160N42AFM key specifications
ParameterValue
Control typeManually operated
Display typeLCD display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Poles4P
Utilization categoryCategory B
IP ratingIP40
Terminal pitch70 mm
Connection surface topFront
Connection surface bottomFront

All specifications

C160N42AFM additional specifications
ParameterValue
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947
Depth147 mm
Width280 mm
Height327 mm
Electrical life cycles1000 cycles at 690 V In 2000 cycles at 690 V In/2 2000 cycles at 440 V In 5000 cycles at 440 V In/2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric C160N42AFM is a ComPacT NS new generation 4-pole moulded-case circuit breaker rated 1600 A at 50 °C, fitted with a MicroLogic 2.0 A electronic trip unit providing L (long-time overload) and I (instantaneous short-circuit) protection. It is a manually operated distribution breaker built to EN/IEC 60947-2, Category B — meaning it is intended for use in distribution panels where selectivity with downstream breakers is required, not just motor-circuit isolation.

Breaking capacity — what the N code means for your system

The N breaking capacity code (50 kA at 415 V AC) tells you this breaker can interrupt 50,000 A of prospective fault current at 380–415 V, 50/60 Hz. At 220–240 V it handles 85 kA Icu; at 690 V it still clears 30 kA. The full Icu curve across voltages means you can apply this breaker upstream without worrying about cascading failure at the lower fault levels common on long cable runs.

Fixed-mount design on a backplate, front-connected both top and bottom. The 280 mm width, 327 mm height, and 147 mm depth fit standard switchboard cubicle compartments — plan for a 70 mm connection pitch between phases. The LCD display on the MicroLogic 2.0 A trip unit gives local ammeter readout and fault indication via four red LEDs plus a yellow overload LED — useful for a quick visual check during commissioning or after a trip event.

Electrical durability and thermal memory

Rated for 1000 electrical cycles at full rated current and 690 V, and 10,000 mechanical cycles — that is a standard durability envelope for a fixed-mount distribution breaker of this size. The 20-minute thermal memory in the MicroLogic 2.0 A trip unit means the breaker remembers the thermal history of the last overload event for 20 minutes after the current drops below the pickup threshold, which prevents nuisance re-closing on a still-hot conductor.