Schneider Electric C160N42AFM — Miniature Circuit Breakers (MCB)

Schneider Electric C160N42AFM ComPacT NS 1600A, 4P, 50kA 415

MPNC160N42AFM
Active

Schneider Electric ComPacT NS new generation, C160N42AFM, 4-pole MCCB, 1600 A at 50 °C, MicroLogic 2.0 A electronic trip unit, 50 kA Icu at 415 V AC, fixed mount, front connection.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

C160N42AFM — Identification
ParameterValue
Product nameComPacT NS new generation
Product rangeComPacT
Product range (series)ComPacT NS630b...1600 new generation
Product/component typeCircuit breaker
Device applicationDistribution
C160N42AFM — Ratings
ParameterValue
Rated current (In)1600 A at 50 °C
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)37 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 37 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 37 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)8 kV conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory B
Overvoltage categoryIII
C160N42AFM — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)1000 cycles at 690 V In 2000 cycles at 690 V In/2 2000 cycles at 440 V In 5000 cycles at 440 V In/2
Mechanical durability (cycles)10000 cycles
C160N42AFM — Mechanical
ParameterValue
Mounting supportBackplate
Mounting modeFixed
Control typeManually operated
Local signalling/indication4 LEDs (red) for fault indication 1 LED (yellow) for overload
C160N42AFM — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947
Relative humidity0...95 %
C160N42AFM — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C160N42AFM — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.4...1 x In
Trip unit protection functionsLI

Product details

The Schneider Electric C160N42AFM is a ComPacT NS new generation 4-pole moulded-case circuit breaker rated 1600 A at 50 °C, fitted with a MicroLogic 2.0 A electronic trip unit providing L (long-time overload) and I (instantaneous short-circuit) protection. It is a manually operated distribution breaker built to EN/IEC 60947-2, Category B — meaning it is intended for use in distribution panels where selectivity with downstream breakers is required, not just motor-circuit isolation.

Breaking capacity — what the N code means for your system

The N breaking capacity code (50 kA at 415 V AC) tells you this breaker can interrupt 50,000 A of prospective fault current at 380–415 V, 50/60 Hz. At 220–240 V it handles 85 kA Icu; at 690 V it still clears 30 kA. The full Icu curve across voltages means you can apply this breaker upstream without worrying about cascading failure at the lower fault levels common on long cable runs.

Fixed-mount design on a backplate, front-connected both top and bottom. The 280 mm width, 327 mm height, and 147 mm depth fit standard switchboard cubicle compartments — plan for a 70 mm connection pitch between phases. The LCD display on the MicroLogic 2.0 A trip unit gives local ammeter readout and fault indication via four red LEDs plus a yellow overload LED — useful for a quick visual check during commissioning or after a trip event.

Electrical durability and thermal memory

Rated for 1000 electrical cycles at full rated current and 690 V, and 10,000 mechanical cycles — that is a standard durability envelope for a fixed-mount distribution breaker of this size. The 20-minute thermal memory in the MicroLogic 2.0 A trip unit means the breaker remembers the thermal history of the last overload event for 20 minutes after the current drops below the pickup threshold, which prevents nuisance re-closing on a still-hot conductor.

Frequently asked questions

What is the breaking capacity of C160N42AFM at 415 V?

50 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2. The N code designates this 50 kA level at 415 V.

Where can I buy C160N42AFM and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

What is the closest alternative to C160N42AFM in the ComPacT family?

Within the ComPacT NS new generation range, the closest sibling would be a breaker with the same frame size and trip rating but a different breaking capacity code (e.g., S or H) or a different MicroLogic trip unit version. The deciding factor for a substitution is whether your system's available fault current at the point of installation is below the alternative's Icu rating — the N code at 50 kA 415 V is the mid-range option; an S code (36 kA) or H code (70 kA) would serve a lower or higher fault level respectively.

MPN
C160N42AFM