Schneider Electric ComPacT NS new generation, C160N45EFM, 4-pole molded case circuit breaker, 1600 A, MicroLogic 5.0 E electronic trip unit, 85 kA Icu at 240 V AC.

$3,809.10 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C160N45EFM key specifications
ParameterValue
Control typeManually operated
Display typeLCD display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Poles4P
Utilization categoryCategory B
IP ratingIP40
Terminal pitch70 mm
Connection surface topFront

All specifications

C160N45EFM additional specifications
ParameterValue
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947
Depth147 mm
Width280 mm
Height327 mm
Electrical life cycles1000 cycles at 690 V In 2000 cycles at 690 V In/2 2000 cycles at 440 V In 5000 cycles at 440 V In/2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The C160N45EFM is a 4-pole ComPacT NS new generation molded case circuit breaker rated 1600 A at 50 °C, with a MicroLogic 5.0 E electronic trip unit that provides L (long-time overload), S (short-time short-circuit), and I (instantaneous short-circuit) protection. The IEC 60947-2 Category B utilization confirms it is designed for selectivity in distribution, not just cable protection. At 147 mm deep, 280 mm wide, and 327 mm tall, this fixed-mount breaker bolts to a backplate with a 70 mm connection pitch. The front-facing connections (upside and downside) simplify busbar or cable routing in a switchboard — no rear-access required. IP40 front face and IK07 impact rating handle the usual panel environment; pollution degree 3 means it tolerates conductive dust in industrial enclosures.

Deployment context

This breaker is sized for main or feeder protection in a 1600 A distribution switchboard — think a factory main incoming, a large motor control center, or a data-center PDU. The MicroLogic 5.0 E trip unit includes an energy meter (type of measurement: energy meter), so it doubles as a revenue-grade metering point without an extra CT cabinet. The LCD display shows real-time current, energy, and trip data locally. Mechanical durability is 10,000 cycles; electrical durability ranges from 1,000 cycles at 690 V In up to 5,000 cycles at 440 V In/2. That is typical for a distribution breaker — not rated for frequent switching like a contactor, but fine for infrequent disconnect duty. The 20-minute thermal memory means the trip unit remembers prior heating, so a reclose after a near-trip event is safer.