Skip to main content
Schneider Electric C160N460FM

Schneider Electric C160N460FM ComPacT NS Circuit Breaker, 16

MPN C160N460FM
Active

Schneider Electric ComPacT NS new generation, C160N460FM, 4P circuit breaker, 1600 A, MicroLogic 6.0 trip unit, 85 kA Icu at 240 V AC, IP40.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C160N460FM key specifications
ParameterValue
Control typeManually operated
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Poles4P
Utilization categoryCategory B
IP ratingIP40
Terminal pitch70 mm
Connection surface topFront
Connection surface bottomFront

All specifications

C160N460FM additional specifications
ParameterValue
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degree3 conforming to IEC 60947
Depth147 mm
Width280 mm
Height327 mm
Electrical life cycles1000 cycles at 690 V In 2000 cycles at 690 V In/2 2000 cycles at 440 V In 5000 cycles at 440 V In/2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

It carries a MicroLogic 6.0 electronic trip unit that provides L (long-time overload), S (short-time short-circuit), I (instantaneous short-circuit), and G (ground fault) protection — so a single device covers thermal, magnetic, and earth-leakage coordination without external relays. The 85 kA Icu at 240 V AC (50 kA at 415 V) means it can safely interrupt fault currents up to that level under IEC 60947-2, which is the standard for low-voltage switchgear and controlgear.

Fixed-mount design on a backplate, 327 mm high by 280 mm wide by 147 mm deep. The 70 mm connection pitch and front-facing terminals on both line and load sides simplify busbar alignment and cable entry in a panel. IK07 impact rating (conforming to EN 50102) handles accidental tool drops during maintenance.

The 20-minute thermal memory means the trip curve remembers prior heating events for that window, which prevents nuisance tripping on repetitive inrush while still protecting against sustained overloads.

MPN
C160N460FM