Schneider Electric C160N460FM — Residual Current Breakers (RCCB/RCBO)

Schneider Electric C160N460FM ComPacT NS Circuit Breaker, 16

MPNC160N460FM
Active

Schneider Electric ComPacT NS new generation, C160N460FM, 4P circuit breaker, 1600 A, MicroLogic 6.0 trip unit, 85 kA Icu at 240 V AC, IP40.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

C160N460FM — Residual Current Protection
ParameterValue
Trip unit technologyElectronic
Local signalling / indication4 LEDs (red) for fault indication 1 LED (yellow) for overload
C160N460FM — Electrical Ratings
ParameterValue
Rated current (In)1600 A at 50 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz
Number of poles4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)8 kV conforming to IEC 60947-2
Overvoltage categoryIII
Electrical durability1000 cycles at 690 V In 2000 cycles at 690 V In/2 2000 cycles at 440 V In 5000 cycles at 440 V In/2
Mechanical durability (operating cycles)10000 cycles
C160N460FM — Identification
ParameterValue
Product nameComPacT NS new generation
Product / component typeCircuit breaker
Product range / familyComPacT
C160N460FM — Mechanical
ParameterValue
Mounting supportBackplate
Mounting modeFixed
Control typeManually operated
C160N460FM — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C160N460FM — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

It carries a MicroLogic 6.0 electronic trip unit that provides L (long-time overload), S (short-time short-circuit), I (instantaneous short-circuit), and G (ground fault) protection — so a single device covers thermal, magnetic, and earth-leakage coordination without external relays. The 85 kA Icu at 240 V AC (50 kA at 415 V) means it can safely interrupt fault currents up to that level under IEC 60947-2, which is the standard for low-voltage switchgear and controlgear.

Fixed-mount design on a backplate, 327 mm high by 280 mm wide by 147 mm deep. The 70 mm connection pitch and front-facing terminals on both line and load sides simplify busbar alignment and cable entry in a panel. IK07 impact rating (conforming to EN 50102) handles accidental tool drops during maintenance.

The 20-minute thermal memory means the trip curve remembers prior heating events for that window, which prevents nuisance tripping on repetitive inrush while still protecting against sustained overloads.