Specifications

C16B4 key specifications
ParameterValue
Control typeToggle
Protection typeWithout protection
Main product or component typeBasic frame
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C

All specifications

C16B4 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth86 mm
Width140 mm
Height161 mm
Electrical life cycles40000 cycles 440 V AC 50/60 Hz In/2 conforming to IEC 60947-2 15000 cycles 690 V AC 50/60 Hz In/2 conforming to IEC 60947-2 20000 cycles 440 V AC 50/60 Hz In conforming to IEC 60947-2 7500 cycles 690 V AC 50/60 Hz In conforming to IEC 60947-2
Mechanical life cycles40000 cycles conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-25...70 °C

Product details

What this basic frame gives you

It ships without a trip unit, so you pair it with the appropriate electronic or thermal-magnetic trip module for your load. At 440 V AC it still holds 20 kA Icu; at 500 V AC it drops to 15 kA. That's a solid selectivity window for a 160 A panel feeder.

It's a panel-mount breaker, not a DIN-rail snap-on, so plan for screw-down mounting and busbar takeoffs.

Mechanical durability is 40,000 cycles per IEC 60947-2. Electrical durability varies with voltage and load: 40,000 cycles at 440 V AC at half rated current (In/2), 20,000 cycles at full In at 440 V AC, and 7,500 cycles at 690 V AC at full In. That's a lot of switching for a distribution breaker — it's not just a backup isolator, it's rated for regular load switching.

MPN