Skip to main content
Schneider Electric C25F3MA150

Schneider Electric C25F3MA150 ComPacT NSX 150A MCCB, 85kA

MPN C25F3MA150
Obsolete

Schneider Electric ComPacT NSX, circuit breaker, 3P, 150 A, MA magnetic trip unit, 85 kA Icu at 240 V AC, F breaking capacity 36 kA at 415 V AC, EN/IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C25F3MA150 key specifications
ParameterValue
Control typeToggle
Trip unit typeMagnetic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 35 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 15 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C

All specifications

C25F3MA150 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth86 mm
Width105 mm
Height161 mm
Electrical life cycles20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical life cycles20000 cycles
ApplicationMotor protection
Operating temperature-25...70 °C

Product details

It's a 3-pole, 3-protected-pole device that provides short-circuit protection only — no thermal overload function, because that's handled by the motor starter or overload relay downstream. That makes it a straight magnetic-only breaker for the feeder or branch circuit feeding a motor, where you want magnetic trip for faults but leave the overload protection to the contactor's overload block. Rated 150 A at 65 °C, it's a 150 A frame breaker fitted with a 150 A trip unit — no derating guesswork at typical panel ambient. The breaking capacity is substantial: 85 kA Icu at 240 V AC, 36 kA at 415 V AC, and still 22 kA at 525 V AC, all per IEC 60947-2. That's enough for most industrial distribution systems with decent fault current headroom.

Where it fits — panel and system integration

IP40 enclosure protection keeps tools and fingers out; IK07 impact rating handles accidental knocks during installation. Horizontal or vertical mounting is fine — no restriction. The toggle control is manual, so it's a straightforward panel breaker, not a motorized or remote-operated unit. Five accessory slots are available for shunt trips, auxiliary contacts, or undervoltage releases.

Mechanical endurance is 20,000 cycles; electrical endurance varies by load: 20,000 cycles at 440 V at half rated current (In/2), 10,000 cycles at full rated current (In) at 440 V, and 5,000 cycles at 690 V at In/2. For a motor-protection breaker that sees occasional switching (not daily contactor duty), that's plenty. The utilization category is A — meaning it's not intended for frequent switching under load, which is standard for an MCCB in a motor branch circuit. Power dissipation per pole is 8.55 W, so three poles total about 25.7 W — factor that into panel thermal calculations.

MPN
C25F3MA150