Schneider Electric ComPacT NSX series, NSX250N frame, 3-pole, 150 A magnetic-only MA trip unit, 50 kA Icu at 415 V AC, toggle control.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C25N3MA150 key specifications
ParameterValue
Control typeToggle
Trip unit typeMagnetic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz
Breaking capacity90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 50 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 15 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C

All specifications

C25N3MA150 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth86 mm
Width105 mm
Height161 mm
Electrical life cycles20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical life cycles20000 cycles
ApplicationMotor protection
Operating temperature-25...70 °C

Product details

The MA trip unit provides magnetic-only short-circuit protection (I), meaning it responds to fault currents but not overloads — the motor's own overload relay handles that. This is standard practice for motor branch circuits where the breaker is sized for the short-circuit rating and the starter provides thermal protection. The 35 mm connection pitch matches standard busbar systems.

Breaking capacity and selectivity headroom

The N breaking capacity code delivers 50 kA Icu at 380/415 V AC and 440 V AC, 36 kA at 500 V, and 35 kA at 525 V per IEC 60947-2. At 480 V AC under UL 60947-4-1 it holds 50 kA. Rated for isolation (EN/IEC 60947-2), pollution degree 3, overvoltage category III. Suitability for isolation means you can use it as a visible-break disconnect for the motor circuit — no separate isolator needed.

Integration notes for the panel

IP40 front face, IK07 impact resistance. Five accessory slots for auxiliary contacts, shunt trips, or under-voltage releases. Electrical durability: 20,000 cycles at 440 V at In/2, 10,000 at full In. Mechanical durability 20,000 cycles. That's typical for a motor-circuit breaker — not a switching device, but rated for occasional isolation and fault clearing.