Skip to main content
Schneider Electric C25V3TM160

C25V3TM160 ComPacT NSX 160 A, 85 kA Icu, Thermal-Magnetic

MPN C25V3TM160
Active

Schneider Electric ComPacT NSX circuit breaker, 160 A, 3-pole, TM-D thermal-magnetic trip unit, 85 kA Icu at 500 V AC, IEC 60947-2.

$986.71 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C25V3TM160 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz
Breaking capacity85 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 80 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 75 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C

All specifications

C25V3TM160 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth86 mm
Width105 mm
Height161 mm
Electrical life cycles20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The C25V3TM160 is a Schneider Electric ComPacT NSX circuit breaker with a 160 A TM-D thermal-magnetic trip unit, rated 85 kA Icu at 500 V AC per IEC 60947-2. The TM-D trip gives you fixed thermal overload (L) and fixed magnetic short-circuit (I) protection; no interchangeable rating plugs, so what you order is what protects the circuit.

The 105 mm width, 161 mm height, and 86 mm depth fit standard ComPacT NSX panel cutouts; if you're retrofitting an older NS or NSJ breaker, check the door cutout and busbar centers because the mounting footprint changed between generations.

If your panel runs hotter, expect a reduction; the trip unit is thermal-magnetic so the thermal element responds to both current and ambient temperature. Power dissipation is 11.78 W per pole, so three poles at 160 A shed about 35 W total — plan ventilation if the enclosure is sealed and densely packed.

MPN
C25V3TM160