Skip to main content
Schneider Electric C25V3TM160 — Miniature Circuit Breakers (MCB)

C25V3TM160 ComPacT NSX 160 A, 85 kA Icu, Thermal-Magnetic

MPNC25V3TM160
Active

Schneider Electric ComPacT NSX circuit breaker, 160 A, 3-pole, TM-D thermal-magnetic trip unit, 85 kA Icu at 500 V AC, IEC 60947-2.

$986.71Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C25V3TM160 — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C25V3TM160 — Ratings
ParameterValue
Rated current (In)160 A at 40 °C
Poles configuration3P
Breaking capacity85 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 80 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 75 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)85 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 80 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 75 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C25V3TM160 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C25V3TM160 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C25V3TM160 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C25V3TM160 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C25V3TM160 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The C25V3TM160 is a Schneider Electric ComPacT NSX circuit breaker with a 160 A TM-D thermal-magnetic trip unit, rated 85 kA Icu at 500 V AC per IEC 60947-2. The TM-D trip gives you fixed thermal overload (L) and fixed magnetic short-circuit (I) protection; no interchangeable rating plugs, so what you order is what protects the circuit.

The 105 mm width, 161 mm height, and 86 mm depth fit standard ComPacT NSX panel cutouts; if you're retrofitting an older NS or NSJ breaker, check the door cutout and busbar centers because the mounting footprint changed between generations.

If your panel runs hotter, expect a reduction; the trip unit is thermal-magnetic so the thermal element responds to both current and ambient temperature. Power dissipation is 11.78 W per pole, so three poles at 160 A shed about 35 W total — plan ventilation if the enclosure is sealed and densely packed.

Frequently asked questions

How do I get pricing and availability for C25V3TM160?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels.

What is the breaking capacity of C25V3TM160?

85 kA Icu at 500 V AC 50/60 Hz per IEC 60947-2, with 80 kA at 525 V and 75 kA at 660/690 V AC. That HB1 breaking capacity code means it's suited for high-fault panels where standard breakers would fail.

MPN
C25V3TM160