Skip to main content
Schneider Electric C25W46E250

Schneider Electric C25W46E250 ComPacT NSX 250A, 100kA 690V

MPN C25W46E250
Active

Schneider Electric ComPacT NSX, NSX250HB2, 4P, 250 A, MicroLogic 6.2 E electronic trip unit, 100 kA Icu at 690 V AC, toggle control, LCD display.

$13.63 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C25W46E250 key specifications
ParameterValue
Control typeToggle
Display typeLCD display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-40 °C

All specifications

C25W46E250 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degreeclass 3
Depth86 mm
Width140 mm
Height161 mm
Electrical life cycles20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

250 A MCCB with ground-fault trip — MicroLogic 6.2 E

The Schneider Electric C25W46E250 is a ComPacT NSX250HB2 molded case circuit breaker with a 250 A frame at 40 °C, fitted with a MicroLogic 6.2 E electronic trip unit. This is a 4-pole unit with front-connect terminals, rated for distribution duty per EN/IEC 60947-2. The trip unit provides L (long-time overload), S (short-time short-circuit), I (instantaneous), and G (ground-fault) protection — the G function is the distinguishing feature here, making this breaker suitable for systems where ground-fault coordination is required, such as on IT or TN-S networks with sensitive earth-leakage detection.

Rated 100 kA Icu at 500 V AC, 525 V AC, and 660/690 V AC (50/60 Hz) per IEC 60947-2. That is a consistent high-interrupting rating across the voltage band — not a derated figure at the top end. For a site electrical engineer coordinating a distribution board, this HB2 (100 kA at 690 V) grade means the breaker can be placed upstream of lower-rated devices without exceeding its short-circuit withstand. The utilisation category is A, so it is not intended for reverse-feed or bidirectional current flow applications without manufacturer guidance.

Mounts on a backplate (not DIN rail) — the 161 mm height, 140 mm width, and 86 mm depth fit standard ComPacT NSX cutouts. Neutral is on the left.

Durability and metering capability

Mechanical durability is 20,000 cycles; electrical durability is 20,000 cycles at 440 V at half-rated current, 10,000 cycles at full 440 V, and 5,000 cycles at 690 V full load. The MicroLogic 6.2 E includes an energy meter function and communicates time-stamped event histories, maintenance indicators, power quality data, and demand values — useful for a facility engineer tracking load profiles without a separate power meter.