Skip to main content
Schneider Electric C40R36E400

Schneider Electric C40R36E400 ComPacT NSX 400A, 200kA MCCB

MPN C40R36E400
Active

Schneider Electric, ComPacT NSX series, NSX400R, C40R36E400, 400 A MCCB with MicroLogic 6.3 E electronic trip unit, 200 kA breaking capacity at 415 V AC, 3-pole.

$35.33 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C40R36E400 key specifications
ParameterValue
Control typeToggle
Display typeLCD display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz
IP ratingIP40
Terminal pitch45 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-40 °C

All specifications

C40R36E400 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degreeclass 3
Depth110 mm
Width140 mm
Height255 mm
Electrical life cycles12000 cycles at 440 V In/2 6000 cycles at 440 V In 6000 cycles at 690 V In/2 3000 cycles at 690 V In
Mechanical life cycles15000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The C40R36E400 is a Schneider Electric ComPacT NSX400R moulded-case circuit breaker (MCCB) from the ComPacT NSX family, rated 400 A at 40 °C with a MicroLogic 6.3 E electronic trip unit. It's a 3-pole, 50/60 Hz device built to EN/IEC 60947-2, which governs low-voltage switchgear and controlgear — the standard that defines breaking capacity, utilisation category, and coordination requirements for industrial distribution. At 690 V AC it holds 45 kA Icu. The MicroLogic 6.3 E trip unit provides L (long-time overload), S (short-time short-circuit), I (instantaneous), and G (ground-fault) protection curves — all adjustable. The electronic trip gives you thermal memory that remembers the last 20 minutes of heating before and after a trip, so reclose-and-trip cycles don't let the cable overheat. It also includes an energy meter and communicates maintenance indicators, demand values, power quality data, and time-stamped event logs. Mechanical durability is 15,000 cycles; electrical durability runs 12,000 cycles at 440 V at half rated current, 6,000 at full rated current — enough for a main breaker in a distribution panel that sees infrequent switching. IP40 and IK07 give it basic indoor panel protection against solid objects and 2 J impact.

The 140 mm width, 255 mm height, and 110 mm depth fit a standard MCCB cutout in a backplate-mounted panel. Toggle control with an LCD display on the trip unit gives local status and settings visibility without opening the door.

MPN
C40R36E400