Skip to main content
Schneider Electric C60H2P10AC

Schneider C60H2P10AC MCB, C-Curve 10A 1P+N, 10kA

MPN C60H2P10AC
Obsolete

Schneider Electric C60H2P10AC, Multi9 C60H series, 1P+N miniature circuit breaker, C-curve 10 A, 10 kA breaking capacity at 440 V AC, 35 mm DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C60H2P10AC specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
Depth73 mm
Width36 mm
Height81 mm
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric C60H2P10AC is a 1P+N miniature circuit breaker from the Multi9 C60H range, rated 10 A at 30 °C with a C-curve (magnetic trip 5–10 × In). It occupies 4 modular pitches (36 mm wide) on a 35 mm symmetrical DIN rail, making it a direct drop-in for any Multi9 distribution board — no need to gut the existing layout to swap in a modern unit. Breaking capacity hits 10 kA Icu at 440 V AC (IEC 60947-2), 15 kA at 400–415 V, and 30 kA at 230–240 V — enough headroom for most commercial and light industrial sub-distribution panels. The 1P+N configuration (neutral left, one protected pole) suits single-phase final circuits where you want overcurrent protection on the phase and a switched neutral.

Rated operational voltage 440 V AC, insulation voltage 500 V AC — the part is isolation-suitable per IEC 60947-2, so you can use it as a disconnecting means with the contact position indicator showing ON/OFF state through the toggle. Mechanical durability rated at 20,000 cycles — fine for distribution duty where the breaker isn't switched daily. Tunnel-type terminals are straightforward for panel builders. Tropicalisation level 2 per IEC 60068-1 and 95% RH at 55 °C means it handles humid environments without derating — relevant for Southeast Asia or coastal installations.

MPN