Schneider Electric C60H2P40AC

Schneider Electric C60H2P40AC C60H MCB, 40 A, C Curve, 1P+N

MPN C60H2P40AC
Obsolete

Schneider Electric Multi9 C60H, C60H2P40AC, miniature circuit breaker, 40 A rated current, C curve, 1P+N, breaking capacity 10 kA at 440 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C60H2P40AC specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
Depth73 mm
Width36 mm
Height81 mm
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric C60H2P40AC is a Multi9 C60H miniature circuit breaker (MCB) rated at 40 A at 30 °C, with a C curve (magnetic trip at 5 to 10 times In). The thermal-magnetic trip handles overloads and short circuits, and the breaking capacity reaches 30 kA at 230-240 V AC, 15 kA at 400-415 V AC, and 10 kA at 440 V AC (all per IEC 60947-2).

DIN-rail fit and panel space

The breaker occupies 4 modules of 9 mm pitch (36 mm total width), 81 mm tall, 73 mm deep. That 73 mm depth is the dimension to watch when you're laying out a shallow enclosure — it's the body depth, not including the toggle throw. Terminals accept up to 35 mm² rigid or 25 mm² flexible wire; strip length is 14 mm, and the recommended tightening torque is 3.5 N·m. The tunnel-type terminals are the standard cage-clamp style, so a good screwdriver with a parallel tip (not a pozi) seats the conductor cleanly.

The C curve (5-10 x In) means the magnetic trip kicks in between 200 A and 400 A. That's the standard curve for general-purpose distribution — lighting, socket outlets, small motor circuits where inrush isn't extreme. The limitation class is 3 per IEC 60947-2, which limits let-through energy — important for downstream cable protection.

MPN
C60H2P40AC