Schneider Electric C60H2P40AC — 1-Pole MCB (DIN Rail)

Schneider Electric C60H2P40AC C60H MCB, 40 A, C Curve, 1P+N

MPNC60H2P40AC
Obsolete

Schneider Electric Multi9 C60H, C60H2P40AC, miniature circuit breaker, 40 A rated current, C curve, 1P+N, breaking capacity 10 kA at 440 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

C60H2P40AC — Identification
ParameterValue
Product nameC60
Product / component typeMiniature circuit-breaker
Product rangeMulti9
Device short nameC60H
Poles description1P + N
Number of protected poles1
Device applicationDistribution
C60H2P40AC — Electrical & Protection
ParameterValue
Rated current (In)40 A at 30 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu / AIR)10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
C60H2P40AC — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals25 mm² flexible Tunnel type terminals35 mm² rigid
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Width36 mm
Height81 mm
Depth73 mm
Tightening torque (by circuit)3.5 N.m
C60H2P40AC — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...70 °C
C60H2P40AC — Electrical
ParameterValue
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2

Product details

The Schneider Electric C60H2P40AC is a Multi9 C60H miniature circuit breaker (MCB) rated at 40 A at 30 °C, with a C curve (magnetic trip at 5 to 10 times In). The thermal-magnetic trip handles overloads and short circuits, and the breaking capacity reaches 30 kA at 230-240 V AC, 15 kA at 400-415 V AC, and 10 kA at 440 V AC (all per IEC 60947-2).

DIN-rail fit and panel space

The breaker occupies 4 modules of 9 mm pitch (36 mm total width), 81 mm tall, 73 mm deep. That 73 mm depth is the dimension to watch when you're laying out a shallow enclosure — it's the body depth, not including the toggle throw. Terminals accept up to 35 mm² rigid or 25 mm² flexible wire; strip length is 14 mm, and the recommended tightening torque is 3.5 N·m. The tunnel-type terminals are the standard cage-clamp style, so a good screwdriver with a parallel tip (not a pozi) seats the conductor cleanly.

The C curve (5-10 x In) means the magnetic trip kicks in between 200 A and 400 A. That's the standard curve for general-purpose distribution — lighting, socket outlets, small motor circuits where inrush isn't extreme. The limitation class is 3 per IEC 60947-2, which limits let-through energy — important for downstream cable protection.

Frequently asked questions

How do I get current pricing and availability for C60H2P40AC?

Submit an RFQ through your preferred independent distribution channel. Availability and current pricing are confirmed at quote time — no stock count or price is listed here, but the part is sourced to order.

What is the closest alternative to C60H2P40AC in the same family?

Within the Multi9 C60 range, the C60H2P40AC is a 1P+N, 40 A, C curve unit. If you need a 2-pole (2P) version with the same rating and curve, look at the C60H2P40 (2P, no switched neutral). The footprint changes to 2 modules wide instead of 4, so verify DIN-rail space before swapping.

What is C60H2P40AC's listed depth?

The depth is 73 mm, measured from the DIN-rail mounting surface to the front of the toggle. That's the body depth — add clearance for wire bending and the toggle throw.

What is C60H2P40AC's listed range?

It belongs to the Multi9 range, which is Schneider Electric's family of miniature circuit breakers and residual current devices for distribution panels.

What compliance documentation does this brand provide for C60H2P40AC?

The breaker is designed to IEC 60947-2 and IEC 60068-1 (tropicalisation class 2). It carries ON/OFF indication and a contact position indicator. For specific certifications (UL, CSA, CE, RoHS, REACH), refer to the manufacturer's declaration of conformity — that documentation is available from Schneider Electric's support portal.

MPN