Skip to main content
Schneider Electric C60H3P25AC

Schneider Electric C60H3P25AC MCB, C Curve, 25 A, 3P, Multi9

MPN C60H3P25AC
Obsolete

Schneider Electric Multi9 C60H, C60H3P25AC, miniature circuit breaker, 3P, 25 A, C curve, 10 kA at 440 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C60H3P25AC specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
Depth73 mm
Width54 mm
Height81 mm
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric C60H3P25AC is a 3-pole C60H miniature circuit breaker from the Multi9 range, rated 25 A at 30 °C with a C trip curve (magnetic tripping between 5 and 10 times In). The C curve means it handles moderate inrush without nuisance tripping — typical for mixed resistive and light inductive loads in commercial or light industrial distribution. The thermal-magnetic trip unit gives you both overload protection (thermal bimetal) and short-circuit protection (magnetic solenoid) in one package.

This breaker carries a 10 kA Icu at 440 V AC per IEC 60947-2, and 15 kA Icu at 400–415 V AC. At the common 230–240 V level it jumps to 30 kA Icu. That matters for selectivity studies: you need the upstream device to hold while this one clears, and the 10 kA at 440 V gives you headroom in most 400 V distribution boards.

Physical integration and environment

Dimensions: 81 mm high, 54 mm wide (6 x 9 mm pitches), 73 mm deep. Fixed mounting on 35 mm DIN rail. The toggle gives clear ON/OFF indication and a contact position indicator confirms the state of the moving contacts. Earth-leakage protection is handled by a separate block — this is the plain MCB, not an RCBO.

MPN
C60H3P25AC